pragmaticBIM Reference
Rules
Rules make regulations checkable. Each rule names the regulation, the severity and the elements it applies to.
SIA-181-001
Airborne sound insulation meets the requirement
The verified airborne sound insulation of a wall, slab, door or exterior element reaches at least the required value. The acoustic consultant sets the requirement under SIA 181: between rooms from the room pair and the requirement level, for exterior elements from the exterior noise and the noise sensitivity.
SIA 181 Sound insulation in buildings
violation
SIA-181-002
Impact sound level at most the permitted value
The verified impact sound level in the room below a slab does not exceed the maximum permitted value. The acoustic consultant sets the maximum under SIA 181 from the room pair and the requirement level.
SIA 181 Sound insulation in buildings
violation
SIA-181-003
Separating elements between usage units carry a sound insulation requirement
Walls, slabs and doors between rooms of different usage units, or between a usage unit and a room outside it such as the stairwell, need an airborne sound insulation requirement under SIA 181. Without a requirement neither the acoustic verification nor the check of the elements is possible.
SIA 181 Sound insulation in buildings
warning
SIA-181-004
Rooms next to other usage units carry noise load and noise sensitivity
A room of a usage unit that adjoins a room outside its unit through a wall, slab or door needs a noise load and a noise sensitivity. Under SIA 181 the requirement of the separating element depends on both values of the room pair; if one is missing, it cannot be derived.
SIA 181 Sound insulation in buildings
warning
VKF-14-15-001
High-rise buildings: external wall and cladding system made of RF1 materials
The external wall and the external wall cladding system of high-rise buildings are made of RF1 materials. Exceptions are plastic anchors, point back-anchorages of insulation and components of negligible area such as joints or seals.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-002
High-rise buildings: external wall with combustible layers encapsulated on all sides K 60
Where a high-rise external wall consists of single layers containing combustible materials, it counts as RF1 as a whole if it is encapsulated on all sides with K 60 - RF1. The gaps are filled without voids with RF1 materials.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-003
External wall cladding systems: reaction to fire by building height and use
The required reaction-to-fire group of external wall cladding systems rises with building height. In low buildings, RF3 materials generally suffice for other uses, while for accommodation the insulation layer stays RF1.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-004
Medium height: subdivide combustible facade, fire spread at most two storeys
In medium-height buildings with combustible external wall cladding or thermal insulation, the facade is subdivided structurally so that a fire spreads at most two storeys above the storey of origin before the fire brigade attacks. The fire brigade must be able to reach the facade surfaces for firefighting.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-005
Rendered external insulation with combustible insulant: fire barrier at every storey
External thermal insulation composite systems with a combustible insulant on medium-height buildings are a VKF-recognized or equivalent construction, or have a circumferential fire barrier made of an RF1 material with a melting point of at least 1000 °C and at least 0.2 m high at every storey.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-006
Ventilated facades: recognized construction, substructure RF3, fixings RF2
Ventilated facades on medium-height buildings whose cladding or insulation in the ventilated cavity is combustible are VKF-recognized or equivalent constructions. On low and medium-height buildings, rod-shaped substructures made of RF3 materials suffice.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-007
Double-skin facades made of RF1, no storey-spanning box windows
Storey-spanning double-skin facades are made of RF1 materials; combustible linear window profiles are allowed, and with additional measures combustible materials are possible. Storey-spanning box windows are not allowed.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-008
External fabrics and films: reaction to fire, distance and position
Fabrics and films fixed on the outside are made of at least RF2 materials, on facades with an RF1 outer layer at least RF3. Combustible fabrics and films are only possible in front of facade areas without openings and fixed glazing, and keep at least 0.9 m distance in width and height from openable windows.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-009
Materials with critical behaviour (cr) generally not usable indoors
Materials with critical behaviour (cr) are generally not usable inside buildings. Exceptions are cables, single-layer membrane facades and materials under a void-free covering with a minimum thickness of 0.5 mm (RF1), 3 mm (RF2) or 5 mm (RF3).
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-010
Vertical escape routes: reaction to fire of linings and structures
In vertical escape routes (stairwells) of low and medium-height buildings with a structural concept, walls and floors with fire resistance, wall and ceiling linings, classified systems, stretched ceilings and stair and landing structures are made of RF1 materials; floor coverings are at least RF2.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-011
Horizontal escape routes: reaction to fire of linings
In horizontal escape routes of low and medium-height buildings, wall and ceiling linings and classified systems are made of RF1 materials with a structural concept and of RF2 with an extinguishing-system concept; stretched ceilings are RF1 or RF2, one group lower where more than 5 m above walkable areas.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-012
Escape routes: combustible area share at most 10 %
In escape routes, the area share of combustible materials such as luminous panels, pin boards, linings or balustrade infills is at most 10 % of the stairwell floor area per storey or of the floor area of the horizontal escape route. Partial areas are at most 2 m² and keep at least 2 m distance from each other.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-013
Other interior rooms: minimum reaction-to-fire requirements
In interior rooms outside escape routes, RF3 materials generally suffice in low and medium-height buildings. Exceptions: in accommodation and rooms with large occupancy, stretched ceilings are RF1 with a structural concept and RF2 with an extinguishing-system concept.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-014
Interior fit-out: thin coatings and linear substructures where RF1/RF2 is required
Where RF1 is required for interior walls, floors and ceilings, combustible coatings such as paint, wallpaper or veneer up to 1.5 mm thick are allowed on the room side. Where RF1 or RF2 is required, linear substructures such as battens may be RF3, provided the visible side has a closed layer of the required group.
Fire protection directive 14-15 Use of building materials
violation
VKF-14-15-015
Evacuation rooms, airlocks and anterooms: assignment to escape routes
For materials, evacuation rooms count as vertical escape routes, except patient rooms and horizontal escape routes in accommodation. Airlocks count as vertical escape routes, anterooms as horizontal ones.
Fire protection directive 14-15 Use of building materials
violation
VKF-15-15-001
Structure in basements at least R 60
Load-bearing elements below ground need the same fire resistance as the structure of the storeys above, and in any case R 60. Single-family houses including their basement and buildings of small dimensions are exempt.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-002
Fire compartment walls and slabs in basements at least EI 60
Walls and slabs forming fire compartments below ground meet the requirement of their use, and at least EI 60. The check treats every wall or slab with a stated fire resistance of class EI, REI or F as forming a compartment.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-003
Openings in fire compartment walls closed by a fire-rated closure
Doors, windows and other openings in walls that form fire compartments are closed by a fire-rated closure. EI 30 is the usual requirement; where the fire load is very small (e.g. between corridor and staircase) E 30 is enough.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-004
Structure: fire resistance by building height
Load-bearing elements need at least, by building height: low R 30, medium R 60, high-rise R 90. With sprinklers: low no requirement, medium R 30, high-rise R 60.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-005
Floor slabs: fire resistance by building height
Floor slabs forming fire compartments need at least, by building height: low REI 30, medium REI 60, high-rise REI 90. With sprinklers: low EI 30, medium REI 30, high-rise REI 60.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-006
Fire compartment walls: fire resistance by building height
Walls separating fire compartments or horizontal escape routes need at least EI 30 at low and medium height and EI 60 in high-rises (EI 30 with sprinklers). These are the lowest values of the tables; other uses partly require more.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-007
Vertical escape routes: fire resistance by building height
The enclosure of staircases and other vertical escape routes needs at least: low height REI 30, medium height REI 60, high-rise REI 90. These values apply with sprinklers too; other uses partly require more.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-008
Doors to staircases close automatically
Doors leading into a staircase or another vertical escape route have a door closer. Apartment doors and doors of classrooms, single offices and plant rooms are not affected.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-009
Fire separation distance between buildings
Between neighbouring buildings, measured facade to facade: 5 m if both facades are RF1 materials on the outside; 7.5 m if one is combustible on the outside; 10 m if both are.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-010
Office buildings: fire compartment at most 3600 m²
In office buildings a fire compartment covers at most 3600 m² without special proof. All storeys connected without fire resistance count together.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-011
Penetrations through compartment components: firestop of at least 30 minutes
Openings and service penetrations in walls and floors that form fire compartments are closed with fire resistance; the firestop holds for at least 30 minutes. Allowing for thermal expansion, the recess is either filled tightly with RF1 materials or closed with a VKF-recognized firestop system rated EI 30.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-012
Pipes through compartment components: recognized firestop system
Where pipes pass through components that form fire compartments, a VKF-recognized firestop system is used, e.g. a fire collar.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-013
Combustible pipe insulation interrupted at the penetration
Combustible thermal insulation on services is interrupted with RF1 material where the service passes through a wall or floor that forms a fire compartment. For tested and recognized components the VKF recognition applies.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-014
Installation shafts over several storeys: compartment-forming, at least EI 30
Building-services lines running over several storeys are in principle routed in installation shafts that themselves form fire compartments. The shaft enclosure matches the fire resistance of the use-related compartmentation, but at least EI 30.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-015
Inspection openings of installation shafts: EI 30 closure
Inspection openings in installation shafts are closed with fire-rated closures EI 30. In low and medium-height buildings RF1 inspection covers are sufficient where the shaft is subdivided or filled storey by storey.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-016
Installation shafts: horizontal subdivision at every storey
In installation shafts that are closed at the top, the recesses for lines are closed with RF1 materials at every storey.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-017
Installation shafts: separate flue systems and ducts with enhanced requirements
Flue systems, ventilation ducts with enhanced fire protection requirements and similar lines are separated from each other and from the other installations in the same shaft with 30 minutes of fire resistance made of RF1 materials, e.g. fire protection boards.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-018
Housing: dwellings as separate fire compartments
Dwellings are built as separate fire compartments. For single-family houses including their basements and an associated granny flat, no fire resistance is required of structure, walls and floors.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-019
School buildings: fire compartment at most 3600 m², special rooms separate
School operations and associated uses, as well as the gymnasium with its ancillary rooms, may each be combined in one fire compartment. Without special proof the contiguous compartment area is at most 3600 m²; it includes all storeys connected without fire resistance.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-020
Accommodation: guest rooms and technical rooms as fire compartments
In accommodation facilities, guest, inmate, patient and staff rooms, operational technical rooms, examination, treatment and laboratory areas, and technical rooms are each built as fire compartments. Not yet checkable: the model does not identify fire compartments.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-021
Car parks: fire compartments of 4800 m² or 2400 m²
Car parks form their own fire compartments. For underground car parks and closed above-ground car parks the permitted compartment area is 4800 m² if the car park has one storey or the storeys form separate compartments.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-022
High-rise buildings: no inspection openings in safety stairwells, limit fire spread at the slab edge
In high-rise buildings, measures against fire spread are taken at every storey where the floor slab meets the external wall; they are not needed where full extinguishing-system protection is provided. Inspection openings of installation shafts are not located in safety stairwells.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-15-15-023
Transformer rooms: separate fire compartment, at least EI 60
Rooms for transformers are built as separate fire compartments. Their enclosure matches the fire resistance of the use-related compartmentation, but at least EI 60.
Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
violation
VKF-16-15-001
Escape route to an exit or stair at most 50 m
From no point of an interior space may the route to the nearest exit to the outside or the nearest stair (vertical escape route) exceed 50 m. The 50 m apply only where two separate exits or stairs can be reached; otherwise the 35 m limit applies (VKF-16-15-002).
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-002
Escape route with a single exit at most 35 m
Where only one exit to the outside or only one stair serves as vertical escape route, the route from the most remote point of an interior space is limited to 35 m. The model does not show whether a second, independent escape route exists, so the check reports routes above 35 m as a warning.
Fire protection directive 16-15 Escape and rescue routes
warning
VKF-16-15-003
Doors on escape routes: clear width at least 0.90 m
A door that an escape route passes through needs a clear opening width of at least 0.90 m. Depending on the use, smaller sizes are allowed, for example for doors to ancillary or small rooms.
Fire protection directive 16-15 Escape and rescue routes
warning
VKF-16-15-004
Doors on escape routes: clear height at least 2.00 m
Doors on escape routes need a clear passage height of 2.00 m; use-specific deviations are possible. The check reads the overall door height (IfcDoor.OverallHeight): if even that is below 2.00 m, the clear height is too small.
Fire protection directive 16-15 Escape and rescue routes
warning
VKF-16-15-005
Horizontal escape routes at least 1.20 m wide
Corridors and other horizontal escape routes are at least 1.20 m wide, measured between walls or railings. A higher occupancy can require more width.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-006
Stairs on escape routes: width 1.20 m, winding 1.50 m
Straight stairs including landings on escape routes are at least 1.20 m wide. Winding stairs need 1.50 m and an inner tread width of at least 0.15 m.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-007
Number of stairs as vertical escape routes by floor area
A storey without sufficient ground-level exits to the outside needs at least one vertical escape route up to 900 m² of floor area and at least two above 900 m². Rooms for more than 100 people also need two vertical escape routes unless sufficient ground-level exits exist.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-008
Room exits by occupancy
The number and width of a room's exits depend on its occupancy: up to 50 people one exit of 0.90 m; up to 100 people two of 0.90 m each; up to 200 people three of 0.90 m each or two of 0.90 m and 1.20 m; more than 200 people several of at least 1.20 m each.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-009
Doors on escape routes open in the escape direction
Doors on escape routes open in the escape direction and can be opened quickly in that direction at any time without a key or tool. For rooms for at most 20 people the swing direction is free; the check applies only when a connected space has PeakOccupancy above 20 or no occupancy is set.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-010
Keep escape routes clear at all times and use them only for circulation
Escape and rescue routes may serve as ordinary circulation routes but must stay clear and safely usable at all times. Outside the use unit they must not serve any other purpose, for example as storage or waiting areas.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-011
Vertical escape routes lead independently to the outside and are not offset
Vertical escape routes (e.g. stair systems) lead to a safe place outside. Where there are several, they lead there independently of each other.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-012
Escape route within the use unit at most 35 m
Within a use unit the escape route may measure at most 35 m. If the exits do not lead directly outside or into a vertical escape route within these 35 m, a horizontal escape route is needed in between (e.g. a corridor with fire resistance or an access balcony).
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-013
Exit width above 200 people: 0.6 m per 100 or per 60 people
With an occupancy above 200 people, the exits together must be at least 0.6 m wide per 100 people where the route leads outside at ground level, and at least 0.6 m per 60 people where it leads over stairs. Example from the appendix: 400 people over stairs give 4.0 m total width.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-014
External stairs: definition and protected external walls
A stair system counts as an external stair if less than half of its plan area is enclosed by external building walls and half of the facade portion bordering the outside is permanently open, with evenly distributed openings that cannot be closed.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-015
Horizontal escape routes: lead to the vertical route, subdivided above 50 m
Horizontal escape routes lead to a vertical escape route or to a safe place outside. If they are longer than 50 m, fire separations divide them so that escape routes of similar length result.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-016
Access balconies: open, made of RF1, leading to the vertical escape route
Access balconies lead to vertical escape routes and consist of RF1 materials; linear load-bearing members may be combustible. They are permanently open to the outside for at least half, with evenly distributed openings that cannot be closed.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-017
Doors on rescue routes openable from outside, automatic doors suitable
Doors on rescue routes must be openable from outside by the emergency services. Automatic sliding and revolving doors are allowed on escape routes if they ensure escape at all times and are suitable for this use.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-018
Buildings with small dimensions: 35 m escape route, narrower stairs
In buildings with small dimensions the escape route to a safe place outside is at most 35 m and may lead through several rooms within the use unit.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-019
Housing: relaxations for separations, stairs and doors
In residential buildings of low and medium height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes between vertical ones are subdivided with fire resistance, and they match the vertical ones in...
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-020
Office, trade and industry: relaxations and door dimensions
In office buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-021
Schools and day-care centres: relaxations and short routes
In school buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-022
Stairs and ramps with large occupancy: width, steps, gradient
For shops and rooms with large occupancy, the total width of stair flights and landings follows the widest exit of the connected storeys. Stairs wider than 2.4 m are divided by handrails.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-023
Record occupancy, room exits directly onto escape routes
The decisive occupancy determines the number and dimensions of escape routes and is to be recorded in writing and bindingly. Where no binding data exist (e.g. seating plans), area-based assumptions apply and may be adapted to the project.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-024
Shops: circulation routes 1.2 m, main routes 1.8 m, escape streets 3.6 m
Shops must have circulation routes serving escape; where they merge, main circulation routes arise. Circulation routes are at least 1.2 m wide and main routes at least 1.8 m.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-025
Seating: passage 0.45 m, at most 32 or 16 seats per row
In rooms with large occupancy, seats are arranged in rows and interrupted by aisles so that the exits can be reached as directly as possible. The free passage between rows is at least 0.45 m, and circulation routes are at least 1.2 m wide.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-026
Accommodation: horizontal evacuation, hotel room doors, reception
On bed floors of accommodation [a] where sick, care-dependent or assistance-dependent people are housed, the horizontal escape routes are subdivided so that, together with the patient rooms, at least two independent fire compartments allow horizontal evacuation.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-027
Car parks: airlocks or forecourts for compartments above 1200 m²
If exits of a parking area lead into a vertical escape route and the fire compartment area exceeds 1200 m², fire-resistant airlocks or forecourts are to be provided. The fire resistance of the airlocks matches that of the load-bearing structure but is at least EI 30.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-028
Agriculture: two exits for stables above 200 m²
Stables with a floor area above 200 m² need at least two suitably placed, sufficiently large exits through which livestock can also be evacuated. The doors open in the escape direction.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-029
High-rise buildings: safety stairwells with airlocks
In high-rise buildings, storeys above ground are served by safety stairwells. These are vertical escape routes specially protected against the entry of smoke and fire (pressurized smoke control system).
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-16-15-030
Atria and inner courtyards: escape routes only with smoke and heat exhaust, verified
Escape routes across atria and inner courtyards are allowed if smoke and heat exhaust systems ensure safe walkability, shown by a verification. For further fire protection requirements for buildings with atria, the appendix refers to the VKF fire protection explanation on buildings with atria and inner courtyards.
Fire protection directive 16-15 Escape and rescue routes
violation
VKF-17-15-001
Offices, trade, schools, high-rise: escape signs and safety lighting
In office, industrial and trade buildings, school buildings, underground protective structures and high-rise buildings, exits and escape routes are marked with escape signs, and safety lighting is installed in the escape routes.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-002
Accommodation: illuminated escape signs on safety lighting and safety lighting
In accommodation facilities, exits and escape routes are marked with escape signs on safety lighting, and safety lighting is installed in the escape routes. For remote accommodation facilities (e.g. mountain huts) the fire authority decides whether it is needed.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-003
Car parks: safety lighting also in the room, e.g. in driving lanes
In car parks, exits and escape routes are marked with escape signs on safety lighting and the escape routes are fitted with safety lighting. The escape routes within the parking area itself, for example along the driving lanes, also get safety lighting.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-004
Rooms with large occupancy, shops: signs lit continuously
In rooms with large occupancy and in shops, exits and escape routes are marked with escape signs on safety lighting. Their lighting stays on as long as people are in the room.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-005
Escape signs: direction indicators, visibility and height across the escape direction
The escape direction is marked with direction indicators if it is not immediately obvious or if people unfamiliar with the premises are present, for example at changes of direction. Exits that are not immediately recognizable or are used only in emergencies are marked.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-006
Escape signs: visibility not impaired, no confusing green
Decorations, advertising and other fittings do not impair the view of escape signs. Other illuminated signs, inscriptions and mirrors do not distract or cause confusion.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-007
Escape signs: durable, easily recognizable, white on green
Escape signs are durable and large enough to be easily recognizable; the required size depends on the distance from which the meaning must still be clear. According to recognized standards they are rectangular or square, with white arrows and symbols on a green ground.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-008
Lighting of escape signs: safety lighting, afterglow, safety power supply
Where lighting of escape signs is required, it is provided as safety lighting. Signs that are neither lit nor backlit are photoluminescent.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-009
Safety lighting: at least 30 minutes, effective after 15 seconds, not switchable
Safety lighting takes effect in time when the normal lighting fails and lasts at least 30 minutes; if the general power supply fails, it is operating after 15 seconds at the latest.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-010
Safety luminaires: light the floor zone and the route to the open air
In escape and rescue routes, safety lighting adequately lights in particular the floor zone and the way to the exit to the open air. Safety luminaires mounted low above the floor have an unbreakable guard.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-011
Safety lighting in escape routes: at least 1 lux
The illuminance of safety lighting in escape routes is at least 1 lux. Not yet checkable: the model carries no illuminance for luminaires or escape routes.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-012
Power sources for safety purposes: independent of the normal supply
A power supply for safety purposes is needed for the safety lighting of rooms, escape routes and escape signs, and for fire protection installations such as sprinkler pumps and fire-brigade lifts.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-013
Safety power sources: installation room at least EI 30, separation EI 60
Power sources for safety purposes and their controls are installed in fixed positions in rooms with a low fire risk. The installation room matches the fire resistance of the structure or the fire compartments, but at least EI 30; the doors are EI 30.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-014
Distribution network for safety purposes: separate circuits, functional endurance, separation
Circuits for safety purposes are laid independently of other circuits. The distribution network is protected against fire so that functional endurance matches the intended operating time of the connected consumers.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-17-15-015
Acceptance test of safety lighting and safety power supply
Complex projects for safety lighting and power supply for safety purposes, including escape-route marking, are submitted for approval before construction starts when the fire authority requests it. After completion, and after major extensions and changes, the installations are accepted and the test is documented.
Fire protection directive 17-15 Escape route marking, safety lighting, safety power supply
violation
VKF-18-15-001
Extinguishers and hose reels by use and area
Buildings and installations with particular hazards are equipped with suitable, adequately sized means for first-response firefighting; number, type and arrangement depend on occupancy, construction, position, extent and use.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-002
Extinguishing agent matched to fire class and room, portable extinguishers where water is unsuitable
The suitability of extinguishers and extinguishing systems depends on handling, properties and quantity of the agent; adverse side effects count. Fire classes A, B, C, D and F are distinguished.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-003
Extinguishers and fire-fighting pipes clearly visible, easily accessible and marked
Extinguishers and fire-fighting pipes are clearly visible and easily accessible; where needed, markings or signs identify the location. They can be put into operation quickly and simply at any time without outside aids and used as intended.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-004
Extinguishers close to room exits that serve as escape routes, or in escape routes
Within fire compartments, extinguishers are placed in the immediate vicinity of room exits that serve as escape routes, or in escape routes such as corridors and forecourts.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-005
Extinguishers in vertical escape routes only under conditions, hose reels not in safety stairwells
Extinguishers may stand in vertical escape routes if there are no fire doors between vertical and horizontal escape routes, for example in office and school buildings up to 900 m² gross floor area, or if several rooms are accessed directly from the vertical escape route. Hose reels in safety stairwells are not allowed.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-006
Uniform arrangement, open placement or cabinet without weakening the fire resistance
With similar floor plans and room layouts, extinguishers are arranged as uniformly as possible. They stand in the open or in separate cabinets; recessed cabinets must not weaken the fire resistance of compartment-forming walls.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-007
Extinguishers: walking line to the nearest device at most 40 m
Extinguishers are distributed so that a fire can be fought at any point; the walking line to the nearest extinguisher is at most 40 m. In areas with particular fire hazards, additional devices are installed at suitable places.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-008
Hose reels: valve of at least DN 32, form-stable hose up to 40 m with nozzle
A hose reel consists of a shut-off valve with a connection of at least DN 32, a movable connection to the swivelling reel, and a form-stable rubber hose with a shut-off nozzle for jet and spray. In special cases, such as agricultural buildings, an equivalent device may replace the reel.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-009
Hose-reel supply line: at least DN 32 in RF1, 3 bar static pressure, 16 l/min
The supply line to a hose reel is at least DN 32 and made of materials of reaction-to-fire group RF1; combustible pipes are laid under plaster with fire resistance EI 30 or equally protected. A static pressure of 3 bar prevails at the hose reel and the flow is at least 16 l/min.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-010
High-rise buildings: fire-fighting risers with interior hydrants (at least DN 80) or pressure-boosting connection
High-rise buildings are equipped with fire-fighting installations such as wet or dry risers, hose reels with interior hydrants (supply line at least DN 80) or pressure-boosting connections. The requirements are set case by case with the fire protection authority.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-011
Dry and cooling extinguishing systems: scope, subdivision, sizing and pressure relief
The scope of special dry and cooling extinguishing systems is limited to individual rooms, areas and equipment. Arrangement and sizing ensure effective cooling or extinguishing effect; pressure-relief openings are installed and large areas are subdivided.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-012
Safety of people with dry extinguishing systems: pre-warning, self-closing doors, danger sign
Dry extinguishing systems get warning and delay devices if flooding can endanger people. The pre-warning time between the alarm signal and release of the agent is long enough to leave the flooding zone safely from any point.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-013
Release of special extinguishing systems automatic or manual, with signal and internal alarm
Cooling or extinguishing agent can be released automatically or by hand. Systems with automatic release can also be operated by hand.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-18-15-014
Instruction, project, acceptance, periodic inspection and maintenance
Persons responsible for a business instruct staff in the handling of extinguishers and special systems. Projects for dry and cooling extinguishing systems are submitted for approval before construction starts when required, and the systems are accepted and inspected periodically.
Fire protection directive 18-15 Fire-extinguishing equipment
violation
VKF-19-15-001
Sprinkler system by occupancy and use, creditable against fire resistance and compartment size
Depending on occupancy and use, buildings, installations or fire compartments are equipped with an adequately sized sprinkler system. It can be taken into account when setting the fire resistance of structures and compartment-forming walls and floors and the permitted compartment size.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-002
Industry, commerce, offices: sprinklers for exceeded compartments, fast fires, hazardous substances or high fire load
For industrial, commercial and office buildings the fire protection authority can require a sprinkler system if the permitted compartment sizes are exceeded and the system makes sense for the use, if fast-developing fires are expected, the ignition hazard is high, hazardous substances are handled or stored, or the...
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-003
Shops above 2,400 m² compartment area: sprinklers including adjoining storage and service rooms
Shops with more than 2,400 m² compartment area, including the adjoining storage and service rooms, are protected by sprinkler systems and supplemented with manual call points. Not yet checkable: the model does not show use, occupancy, number of storeys and compartment size per fire compartment.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-004
Car parks and garages: sprinklers from 4,800, 2,400 or 9,600 m² and for compact parking above 50 vehicles
Underground garages need sprinklers from 4,800 m² compartment area per storey, multi-storey ones with open connections from 2,400 m². Closed above-ground garages need them from 4,800 m², partly open ones (enclosure with 25 % non-closable openings) from 9,600 m² per storey.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-005
Rooms with large occupancy: sprinklers on request
In buildings and installations with rooms of large occupancy the fire protection authority can require sprinkler systems. Not yet checkable: the model does not show use, occupancy, number of storeys and compartment size per fire compartment.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-006
Protected extent: full protection, partial protection over whole compartments, annexes and canopies
Sprinkler systems should be designed as full protection and cover entire buildings and installations, except expressly exempted rooms separated with fire resistance. Partial protection covers at least one whole fire compartment.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-007
Permitted exceptions from sprinkler protection
Sprinklers can be omitted, among others, in wet rooms without combustible stock, technical rooms with low fire hazard as a separate compartment, small rooms up to 4 m², cold rooms up to 50, 200 or 600 m² depending on insulation and separation, crawl spaces without fire load, vertical escape routes separated with...
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-008
Water unsuitable: substitute measures with equivalent protection in the fire protection concept
Where water is not a suitable extinguishing agent, for example for silos with swelling contents, industrial furnaces and baths with increased hazard, substances that form combustible gases with water, or other endangered areas, substitute measures with equivalent protection are taken in agreement with the fire...
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-009
Sprinkler control room: separate compartment of at least EI 30, between 1st upper floor and 1st basement, secured access
Sprinkler control rooms are located in separate fire compartments with the fire resistance of the use-related compartmentation, at least EI 30, with EI 30 doors.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-010
Water supply: reliable, connection to public network or own supply, nominal operating time 45 to 90 minutes
The sprinkler system requires a powerful, reliable water supply with the required connection capacity and pressure. It is connected to the public network in principle; if its capacity including the reserve for the fire brigade is insufficient, an own, combined or independent supply is needed.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-011
Alerting and control: undelayed internal and external alarm via the fire alarm system
Every response triggers an internal and an external alarm without delay; the external one goes via a VKF-recognised fire alarm system to the public fire alarm receiving point. Faults are signalled visually and audibly and forwarded to a permanently staffed point.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-012
Shut-off valves only in the sprinkler control room; tested components
All plant parts are made of suitable materials and withstand the stresses; only sprinkler components with a declaration of performance or VKF technical information are used. Additives in the extinguishing water need a water-protection approval in addition to the fire protection one.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-19-15-013
Specialist firm, documentation, switch-off, project, acceptance, inspection and general overhaul
Sprinkler systems are planned, installed and maintained by VKF-recognised specialist firms and adapted on changes, extensions or changes of use. The control room holds the system documentation and a logbook, the fire-brigade access holds orientation plans.
Fire protection directive 19-15 Sprinkler systems
violation
VKF-20-15-001
Fire alarm system by occupancy and use, special buildings on request
Depending on occupancy and use, buildings, installations or fire compartments are equipped with an adequately sized fire alarm system. It can be required for early alerting of rescue forces, for early activation of fire protection and building services systems, and in large and complex buildings.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-002
Industry, commerce, offices: monitoring when compartments are exceeded, smouldering fires or ban on water
For industrial, commercial and office buildings the fire protection authority can require monitoring if the permitted compartment sizes are exceeded and the system makes sense for the current use, if slowly developing fires such as smouldering fires are expected, or if water must not be used as extinguishing agent.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-003
Accommodation: fire alarm system with full monitoring by category, number of storeys and persons
In accommodation of category a a fire alarm system with full monitoring is required.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-004
Shops: manual call points added to the sprinkler system; large occupancy on request
In shops the sprinkler system is supplemented with manual call points; in sub-areas or individual rooms a fire alarm system is installed where needed to activate technical fire protection equipment. For rooms with large occupancy the fire protection authority can require a fire alarm system.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-005
Monitoring extent: full monitoring, partial monitoring over whole fire compartments
Fire alarm systems should be designed as full monitoring and then cover entire buildings and installations, except expressly exempted rooms separated with fire resistance.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-006
Areas that may be exempted from monitoring
Exemptions are possible, among others, for installation shafts that are inaccessible or free of ignition hazards, wet rooms without combustible stock, lift shafts with a separate machine room, residential areas separated as a fire compartment, cold rooms up to 50, 200 or 600 m² depending on insulation and...
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-007
Fire-brigade control and indicating unit at a safe, easily accessible location
Fire-brigade control and indicating units of systems with more than one detector zone stand at a safe location that is easily accessible for the fire brigade, in the escape route or at the fire-brigade access. The operating-state indication is in the immediate vicinity, and unobstructed access is ensured.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-008
Alerting: internal and external alarm, delays of at most 3 and 5 minutes
Every response triggers an internal and an external alarm; the external one goes directly to the public fire alarm receiving point. Switch-offs and faults are signalled visually and audibly and forwarded to a permanently staffed point.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-009
Fire-mode controls: activation of fire protection equipment, documented and tested
The fire alarm system can trigger fire doors and shutters, smoke and heat exhaust systems, transport systems and ventilation systems. For selective fire-mode controls the trigger is as a rule not by manual call points, which is considered in the fire protection concept.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-010
Fire alarm control panel: safe location, monitored compartment, several panels in a room with EI 30
Fire alarm control panels and remote indicating panels stand at a safe, easily accessible location; the fire compartment of the panel is monitored.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-011
Detector zones: fire location clearly identifiable, vertical shafts combined
The entire monitored area is divided into detector zones so that the fire location is shown quickly and unambiguously. Vertical escape routes, light, lift and installation shafts and tower-like structures form one common detector zone.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-012
Manual call points in escape routes and hazardous areas, clearly visible, mounting height about 1.5 m
Manual call points are fitted clearly visibly in escape routes, for example at exits, passages, vertical escape routes and extinguishers, and in particularly hazardous areas.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-013
Room indicator lamps at entrances to monitored rooms, at least 1.7 m above floor
So that the fire brigade can quickly locate the fire, indicator lamps are installed at entrances to monitored rooms and at raised floors and hollow ceilings, at least 1.7 m above floor.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-014
Special applications: detectors for high rooms, inaccessible places and special environments with consent
Detectors for special applications are used where point detectors are unsuitable or only partly suitable because of environmental influences or room conditions, for example outdoors, in cable tunnels, high halls, inaccessible voids, fume cupboards, silos or heritage buildings.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-20-15-015
Specialist firm, documentation, switch-off, project, acceptance, inspection and review after 15 years
Fire alarm systems are planned, installed and maintained by VKF-recognised specialist firms, with components covered by a declaration of performance or VKF technical information. Orientation plans at the fire-brigade access and a logbook at the control panel are kept.
Fire protection directive 20-15 Fire alarm systems
violation
VKF-21-15-001
Smoke and heat exhaust by use, position and fire-compartment area
Depending on occupancy, number of storeys, construction type, position and use, fire compartments must be equipped with an adequately sized smoke and heat exhaust system.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-002
Systems without performance proof: system type and sizing by use
For systems without performance proof the directive sets, per use, position and area, which system type is permitted: smoke clearance with fire-brigade fans, mechanical or natural systems. Sizing follows air-change rates by room height or supply and exhaust areas as a percentage of the compartment area.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-003
Vertical escape routes: exhaust opening at the top, directly outdoors
Vertical escape routes get exhaust openings at the top leading directly outdoors: in low and medium-height buildings for accommodation, large occupancy and shops, in medium-height buildings for residential, office, industrial, commercial and school buildings and car parks, unless every storey has ventilation sashes...
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-004
Stairwell exhaust opening: 0.5 m² free, operable from the entrance level
The free geometric ventilation area of the exhaust opening at a vertical escape route is at least 0.5 m². It can be put into operation from the entrance level, and it stays operational during a power failure.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-005
Purge ventilation of vertical escape routes from three basements
Vertical escape routes of buildings with three or more basements get purge ventilation. The fire protection concept sets how many escape routes are purged; every use unit reaches the purged escape route by a safe horizontal access.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-006
Systems with performance proof for large offices, occupancies, sales areas and atria
A smoke and heat exhaust system with performance proof is needed for open-connected multi-storey office compartments above 3,600 m², rooms with over 2,000 people, shops with extinguishing system from 7,200 m² (single-storey) or 3,600 m² (multi-storey), and atria with an escape route or over 2,400 m² floor area.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-007
Safety stairwells: smoke-protection pressurization system with overpressure against the lock
Stair enclosures of safety stairwells that are not reached on every storey through permanently open access balconies or forecourts get a smoke-protection pressurization system. The stair enclosure holds a higher overpressure than the lock.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-008
Functional integrity of plant parts for at least 30 minutes
The system follows the state of the art and is built, sized and maintained so that it is effective and ready for operation at all times.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-009
Exhaust openings: highest point, on façades evenly on two opposite sides
Exhaust openings are placed so that effective smoke clearance is possible without danger to people and buildings, at the highest point of the room, for example in the roof or in the ceiling or roof zone of the façades.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-010
Hot-gas fans: temperature resistance and installation room of at least EI 30
Suitable hot-gas fans are used to extract the smoke gases; they withstand at least 400 °C for the required operating time, in compartments with a water-based extinguishing system and in vertical escape routes at least 200 °C.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-011
Smoke-extraction ducts and dampers: fire resistance of the crossed compartment, dampers at least EI 30
Shafts and ducts withstand the expected stresses and prevent fire and smoke spread when hot fire gases are extracted; length expansion is taken up by fixed points and compensators, and plastic anchors are not permitted for exhaust ducts.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-012
Make-up air: inflow openings near the floor, matched to the exhaust openings
Installing a smoke and heat exhaust system requires that the make-up air needed for effective extraction can flow in. Inflow openings, such as façade openings, doors, gates or windows, are placed near the floor and matched to exhaust openings and extract volumes.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-013
Operation and triggering: manual release at a safe location, automatic release with performance proof
Systems can be started by hand from a location that is safe in case of fire; the control points show operating, fault and out-of-service states. The fire protection authority can additionally require automatic release.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-014
Power supply for safety purposes independent of the general supply
Smoke and heat exhaust systems and smoke-protection pressurization systems are connected to suitable power sources that are independent of the general power supply. Not yet checkable: the model holds no trigger and control points of the system and no power source for safety purposes.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-015
Use of ventilation systems for smoke extraction only if RWA requirements are met
Ventilation and air-conditioning systems may be used for smoke and heat extraction only if the affected plant parts meet the requirements for smoke and heat exhaust systems. Not yet checkable: the model holds no smoke and heat exhaust system and no assignment of one to fire compartments.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-016
Concepts: fire-brigade fans down to the 1st basement, natural systems not below ground, extraction under the ceiling
Smoke clearance with fire-brigade fans assumes response forces on site within 15 minutes of the alarm, needs inlet openings for setting up the fans in addition to the exhaust openings, and below ground is permitted only down to the 1st basement unless supply air comes from outdoors on the same level.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-21-15-017
Project review, acceptance, periodic inspection and maintenance
On request of the fire protection authority, projects are submitted for approval in good time. Systems with performance proof are accepted after an installation certificate exists, as are extensions and substantial changes.
Fire protection directive 21-15 Smoke and heat exhaust systems
violation
VKF-23-15-001
Lift shaft linking several fire compartments with fire resistance
Where a lift links several fire compartments, it sits in a shaft whose enclosure matches the fire resistance of the use-related compartmentation, but at least EI 30. The shaft walls run up to the roof skin; if the shaft ends below, its top closure has the same fire resistance.
Fire protection directive 23-15 Conveying systems
violation
VKF-23-15-002
Lift landing doors: fire resistance by location and building type
Lift landing doors are made of RF1 building materials. Where they open directly into a usage unit, they need E 30, or E 60 under a high fire load (above 1000 MJ/m² in the rooms).
Fire protection directive 23-15 Conveying systems
violation
VKF-23-15-003
Fire-fighting lift: shaft, lobby and landing doors
Access to the fire-fighting lift is on every floor only through lobbies. Shaft and lobbies have fire resistance EI 90, fire-resistant closures and a smoke-control pressurisation system.
Fire protection directive 23-15 Conveying systems
violation
VKF-24-15-001
Heating plant: safe operation, verified products and permanent marking
Heating plant is built and installed so that it operates safely and damage in case of a fault stays limited; all parts withstand the thermal, chemical and mechanical stresses.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-002
Ban on installing heat generators in escape routes, explosion-hazard rooms and rooms with high fire load
Heat generators must not be installed in escape routes, in rooms and zones with fire or explosion hazard, or in rooms with large and very large fire load. Not yet checkable: the model does not show nominal heat output, fuel, type of installation and fire resistance of the boiler room.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-003
Single-family houses and flats: solid-fuel firing units in a room with EI 30
For liquid and gaseous fuels the construction and finish of the installation room are unrestricted.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-004
Boiler room in buildings with several compartments: EI 30 up to 70 kW, EI 60 above, doors EI 30
Firing units stand in separate boiler rooms. Their fire resistance depends on the total nominal heat output: up to 70 kW the use-related compartment value, at least EI 30; above that at least EI 60.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-005
Boiler room with direct access from outdoors: above 1,200 kW on ground floor or lower, above 600 kW from 2nd basement
Boiler rooms on the ground floor or lower for plants above 1,200 kW nominal heat output, and boiler rooms on the second basement or lower for plants above 600 kW, get direct access from outdoors.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-006
Open installation in single-storey halls and commercial buildings with low fire load
In single-storey halls and multi-storey industrial and commercial buildings with use-related compartments, firing units of any output may stand openly if operation requires it, the clearances are kept and the fire load in the room is low.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-007
Ventilation and combustion air: supply from outdoors, openings not closable
Room-air-dependent firing units stand only in ventilated rooms, and combustion air must be supplied from outdoors. Combustion-air openings must not be closed unless a safety device allows operation only with the closure open.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-008
Accessibility, safety devices and shut-off devices of firing units
Units and flue system are easily accessible for operation, maintenance and cleaning at all times.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-009
Base plate, floor protection and wall behind firing units in heat-resistant RF1
On combustible floor constructions firing units stand on a base plate of heat-resistant RF1, individually made units such as tiled stoves on a 0.12 m thick slab of stone, concrete or equivalent. In front of solid-fuel units lies a heat-resistant RF1 floor covering extending 0.4 m in front of the loading opening.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-010
Clearances to combustibles: 0.1 / 0.2 / 0.4 m by surface temperature, 0.8 m and 2 m for radiation
Adequate clearances apply to all combustible materials, as given in the declaration of performance or VKF technical information, otherwise 0.1 m for surface temperatures up to 100 °C, 0.2 m up to 200 °C and 0.4 m up to 400 °C.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-011
Fireplaces, tiled stoves, pellet firing units, commercial kitchens and cookers
For fireplaces the information of the declaration of performance or VKF technical information applies. Tiled and storage stoves keep 0.2 m at the sides, back and top and 0.5 m at the firing opening from combustibles and have cleaning openings.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-012
Mobile firing units and small appliances: clearance, combustion air, no continuous heating without flue
Mobile firing units such as building dryers or air heaters keep as much distance from combustibles as comparable stationary units, need sufficient combustion air and, without direct flue routing, stand only in open halls, shells or well-ventilated rooms, not openly in rooms with large occupancy.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-013
Flue systems: system flues, suitable materials, RF1 insulation, classification and marking
Flue systems and connecting pipes discharge the flue gases safely, can be cleaned and create no fire hazard. Only system flues made of heat-resistant construction products and suitable materials are used; thermal insulation is RF1.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-014
Flue systems: connections, continuous routing and minimum height above roof
Only units that in normal operation do not produce flue gases hotter than the system allows are connected; connecting pipes enter in the same storey and fire compartment.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-015
Flue systems through compartments: EI 60 vertically, compartment value horizontally, distance to combustibles, fill-in
Flue systems running vertically through several compartments have EI 60 of heat-resistant RF1 outside the installation room or sit in such a fire protection element, in single-family houses and flats EI 30; horizontally the fire resistance of the compartment applies.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-016
Explosion flaps, flue fans and cleaning openings
For fuels prone to deflagration, such as fine-grained coal or wood chips, explosion flaps belong in the flue system, in the boiler room close to the connecting pipe entry and at least the cross-section of the flue. Flue fans create positive pressure only if the system is approved for it.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-017
Solid fuels: daily consumption in the installation room, store EI 60, at most 10 m³ in the boiler room
Only a day's consumption may be stored in the installation room, shielded from the unit; larger quantities go into other rooms or outdoors. In single-family houses wood or coal up to 5 m³ is allowed in rooms of any construction.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-018
Heating oil: up to 4,000 l small tanks or 8,000 l steel tanks in a boiler room EI 60, delivery systems not in escape routes
In separate boiler rooms with EI 60, heating oil up to 4,000 l in small tanks or up to 8,000 l in steel tanks may be stored; the directive on hazardous substances applies in addition.
Fire protection directive 24-15 Heating plant
violation
VKF-24-15-019
Operational readiness and maintenance of heating plant
Owners or operators ensure that heating plant is maintained as intended and is ready for operation at all times.
Fire protection directive 24-15 Heating plant
violation
VKF-25-15-001
Air-handling units serving several ventilation sections: separate room with EI 30 and EI 30 doors
Units that serve several ventilation sections are installed in a separate room. Its enclosure matches the fire resistance of the use-related compartmentation, but at least EI 30; the doors are also EI 30.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-002
Outdoor air and exhaust air: safe intake and discharge
Outdoor air is taken directly from the open so that no combustible gases or vapours are drawn in. Exhaust-air ducts discharge to the open so that escaping fire gases and flames do not endanger the surroundings and cannot reach the outdoor-air intake.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-003
Filters and silencers at least RF3, filter liquid with flash point above 160 °C
Filters and silencers are made of at least RF3 materials. Filter liquids have a flash point above 160 °C.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-004
Fans and air-treatment units of RF1, safety devices on air heaters
Fans (except parts of no fire-safety significance) and air-treatment units with their built-in parts (air heaters, coolers, heat recovery, humidifiers) are made of RF1 materials.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-005
Smoke trigger device at the extract connection of systems serving several ventilation sections
Systems that serve several ventilation sections (fire compartments combined for ventilation purposes) have a smoke trigger device at the extract connection. When it responds, it switches the system off and closes the fire dampers.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-006
Ventilation ducts of RF1, exceptions at least RF3
Ventilation ducts, ventilation ceilings and floors are made of RF1 materials. At least RF3 is enough within the fire compartment of ventilation sections in office, school and dwelling units, for ventilation ceilings and floors within one compartment, for ducts cast in concrete and for earth registers.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-007
Hangers and thermal insulation of ventilation ducts
Hangers and fixings of RF1 ducts are also RF1 (except vibration dampers and the like) and hold the duct securely for the required fire resistance duration. Thermal insulation of RF1 ducts is RF1; outdoor-air ducts may use at least RF3 (cr) if covered on all sides with at least 0.5 mm of RF1.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-008
Ducts without openings through other sections: EI 30 or fire dampers
Ventilation ducts that run without openings through other fire or ventilation sections, or whose outlets are on the storey above or below, are built or clad with EI 30. In airlocks and vertical escape routes the fire resistance of the use-related compartmentation applies, at least EI 30.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-009
Inspection and cleaning openings; no foreign installations in ventilation ducts
Ventilation ducts are arranged and fitted with openings so that they can be inspected and cleaned. Only parts that serve the system may be installed in ventilation ducts and air-carrying shafts (except ventilation ceilings and floors).
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-010
Duct penetration through compartment-forming components: firestop EI 30 or RF1 filling
The recess between the ventilation duct and the compartment-forming component is, allowing for thermal expansion, either filled tightly with RF1 materials (e.g. mortar, plaster) or closed with a firestop system that reaches EI 30 in compartment-forming walls and floors.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-011
Fire dampers: at least EI 30-S, actuator, thermal release, self-closing
Fire dampers prevent fire and smoke from spreading through ventilation systems and are rated at least EI 30-S. They are fixed according to the declaration of performance or VKF technical information and the manufacturer's instructions, and are accessible and inspectable from outside.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-012
Fire dampers where ducts cross fire compartments and ventilation sections
Fire dampers are placed where ventilation ducts pass through fire walls and compartment-forming walls and floors, and where ducts without openings run through other ventilation sections without having the required fire resistance themselves.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-013
Omitting fire dampers: permitted exceptions
Fire dampers can be omitted where fire compartments can be combined structurally into ventilation sections; in office and school buildings with a ventilation-section area up to 1,200 m²; in accommodation and residential buildings up to 600 m²; for ventilation of wet cells; with separate duct routing up to the...
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-014
Fire-case control: system switches off automatically on alarm, otherwise manual switch-off
Ventilation systems switch off automatically when fire detection or extinguishing systems, duct smoke detectors or the thermal release of fire dampers respond. Where such devices are missing, the systems can be switched off by hand at an easily accessible place.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-015
Escape routes: no open air routing, ventilation separate or with fire dampers
Escape routes do not replace ventilation ducts for open air routing. Compartment-forming escape routes are in principle ventilated separately from other ventilation systems; otherwise fire dampers belong in the compartment-forming walls, with storey-by-storey subdivision, separate ducts or separate systems.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-016
Kitchen extract: grease separators, RF1 ducts, separate plant rooms from EI 60
Kitchen extract ducts are RF1 (heat-resistant) and have a grease separator or filter near the extraction point. In residential buildings RF1 is enough for hood extract; after the hood and before heat recovery a VKF-recognised shut-off device is installed.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-017
Systems with air temperature above 85 °C: RF1 ducts and safety distances
At air temperatures above 85 °C the ventilation ducts are RF1 (heat-resistant) and keep a distance to combustible material: 0.1 m up to 100 °C, 0.2 m up to 200 °C, 0.4 m up to 400 °C. With a 30-minute cladding of RF1 (heat-resistant) the distances are halved.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-018
Systems for explosion-hazard areas and aggressive media
Systems for fire and explosion hazard areas have separate units and ducts; if the units stand in another area they go in their own room with the fire resistance of the compartmentation, at least EI 60.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-019
Ducts with increased requirements in an installation shaft: separation EI 30
Several ventilation ducts of systems with increased requirements (clauses 4.3.1 to 4.3.3) in the same installation shaft are separated storey by storey and compartment by compartment with a 30-minute fire protection board of RF1; RF1 ducts may instead be clad individually with EI 30 of RF1.
Fire protection directive 25-15 Ventilation systems
violation
VKF-25-15-020
Cleaning, inspection and maintenance of ventilation systems and fire dampers
Ventilation systems are cleaned and maintained so that they are always ready for operation and no fire hazard arises. Fire dampers and fire-case controls are inspected periodically.
Fire protection directive 25-15 Ventilation systems
violation
VKF-26-15-001
Hazardous substances from 100 kg: GHS classification, protection by type and quantity, fire protection concept before construction
The directive covers storage and handling of hazardous substances and preparations from 100 kg, unless other quantities are named. Substances are classified under the GHS, pyrotechnics under explosives law; diesel and heating oil count as combustible without classification.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-002
No hazardous substances in escape routes or in front of exits; on-site overview, instruction, adaptation on change
Hazardous substances must not be kept in passages or drive-throughs, in horizontal or vertical escape routes, or in front of entrances and exits.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-003
Maximum stored quantity per fire compartment: 50 t, 200 t with fire alarm, 600 t with sprinklers (by substance class)
Maximum quantities in tonnes per fire compartment depend on substance classification. For highly flammable, oxidising and self-igniting substances: 50 t without fire alarm or sprinklers, 200 t with a fire alarm, 600 t with sprinklers (2,400 t for rack storage with automatic sprinklers and foam admixture).
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-004
Rooms at fire or explosion risk: zones, pressure relief and fire compartment; storage rooms as fire compartments
Rooms are classified by fire and explosion hazard and divided into zones; type, quantity, frequency and duration of combustible gases, dusts or vapours decide.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-005
Ventilation of hazardous concentrations; fans and ignition sources in hazard zones
Rooms or zones where combustible gases, vapours, mists or dusts can accumulate dangerously are ventilated naturally or artificially to a sufficient extent. Fans and their drives in explosion-hazard zones or in exhaust ducts must not become effective ignition sources.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-006
Lightning protection: gases above 1,000 kg, combustible liquids above 2,000 l, tyre stores, large pyrotechnic stores
Buildings and plant holding hazardous substances are protected against ignition by lightning. Combustible gases: up to 450 kg net no measures, up to 1,000 kg earthing or equipotential bonding of conductive parts, above that a lightning protection system.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-007
Extinguishing equipment in hazard buildings; fire alarm, gas warning or extinguishing systems as needed
In buildings and plant with rooms or zones at fire or explosion risk, suitable extinguishing equipment is installed at suitable places and in sufficient number. Where conditions require it, fire alarm systems, gas warning systems or extinguishing systems are added.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-008
Storage concept, substance segregation in separate fire compartments and hazard signs
A storage concept is drawn up for stores with hazardous substances (inventory, location, type and container, structural, technical and organisational measures).
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-009
Gas cylinders: not in escape routes, ventilated, from 200 l cylinder volume outdoors or in a separate fire compartment
Gas cylinders are protected against excessive heating, mechanical damage and falling over and are not stored together with highly flammable or self-igniting substances. In escape routes they are neither connected nor stored; rooms with connected or stored cylinders are sufficiently ventilated.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-010
Cryogenic tanks outdoors with a 5 m protected zone EI 60; liquefied petroleum gas not in basements
Cryogenic tanks (vacuum-insulated tanks for deep-cooled liquefied oxidising or asphyxiant gases) stand outdoors and not in depressions.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-011
Aerosol packs: stored apart, below 50 °C, from 100 l behind a grille, flammable ones ventilated
Aerosol packs (spray cans) are stored in rooms with low fire risk, locally separated from other stored goods, and kept and used so that they do not warm above 50 °C. Above 100 l they stand behind a grille (e.g. pallet with cage frame, mesh box).
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-012
Combustible liquids: prevent spreading, vapours not into lower rooms, flash point ≤ 23 °C only in permitted containers
Leaking combustible liquids must not spread (e.g. raised door thresholds, drainage channels, separators, drip trays), and their vapours must not reach lower rooms, sewers, shafts or pits. Heating devices are thermally secured; no heating with open flames or unprotected heat sources.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-013
Storage rooms for combustible liquids: EI 30 doors, access opening at least 0.7 × 1 m with an EI 30 cover
Storage rooms for combustible liquids are closed off from other rooms with EI 30 doors. Access to tank rooms is by openings of at least 0.7 × 1 m, closed with EI 30 covers.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-014
Containers and small tanks: requirement for room or cabinet by stored quantity (25 l to over 2,000 l) and flash point
For combustible liquids with a flash point up to 60 °C, per compartment: up to 25 l a room of any construction; 26 - 100 l an RF1 cabinet with collecting tray and marking; 101 - 450 l a room EI 30 with low fire risk; 451 - 2,000 l a room EI 60 without additional fire loads; above 2,000 l a room EI 90 without...
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-015
Medium-sized tanks: up to 10,000 l flash point ≤ 60 °C in a room EI 90, up to 250,000 l above that in a room EI 60
In a room EI 90 without additional fire loads, at most 10,000 l of combustible liquids with a flash point up to 60 °C may be stored; special protective measures are needed (e.g. mechanical ventilation, extinguishing system, gas detection).
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-016
Ventilation for highly flammable liquids: natural openings 20 cm² per m², artificial 3 to 5 air changes, 10 during handling
Storage rooms count as sufficiently naturally ventilated when above ground with at least two opposite non-closable openings to the outside, one of them at most 0.1 m above the floor, each at least 20 cm² per m² of floor area.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-017
Oxidising substances: from 100 kg own fire compartment EI 60, outdoors 5 m distance or screen wall EI 60
Oxidisers may be stored with other hazardous substances in the same compartment up to 100 kg in total, if 2.5 m distance to combustible materials is kept or partition walls EI 30 of RF1 are installed.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-018
Substances with special fire behaviour: closed RF1 containers, dry, stock above need in a separate marked room
Self-igniting substances are kept in closed RF1 containers excluding air, in an inert atmosphere or under regular temperature monitoring.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-019
Open-air tyre stores: area 2,400 or 4,800 m², sections of 100 m² with 10 m spacing, 10 m to buildings
Up to 1 t or less than 10 m² of storage area, no requirements apply. Stores are protected against unauthorised access, and fire protection and fire brigade intervention plans exist.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-020
Tyre stores in buildings: on an exterior wall, EI 60 up to 60 t/600 m², above that EI 90 with sprinklers and foam
Stores are on an exterior wall and have clearing openings of at least 2 × 2 m leading directly outdoors. Up to 100 m² the store may stand in the usage unit without fire-resistant separation.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-021
Petrol pumps outside buildings with 3 m distance or an EI 60 wall without openings
Petrol pumps stand outside buildings and installations and keep 3 m distance from them. The distance may be smaller if the building wall within 3 m on both sides and 1 m above the pump is EI 60 and without openings.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-022
High-bay racking with hazardous substances: extinguishing system, 18 m storage height, ventilation, aisles as fire compartments
High-bay racking is protected with automatic extinguishing systems.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-023
Stores of pyrotechnic articles: cool and dry, locked, EI 30 doors opening in escape direction, extinguishing equipment at the entrance
Pyrotechnic articles stay in their shipping and packaging units. Storage rooms are cool, dry, well ventilated and kept at as constant a temperature as possible.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-024
Pyrotechnic stores by quantity: up to 50 kg EI 30, up to 300 kg EI 60, up to 1,000 kg on an exterior wall, above that free-standing with 20 m distance
Up to 50 kg gross (temporary, at most 1 month) rooms are built EI 30 and, with low fire risk, may serve other purposes. Up to 300 kg gross, rooms EI 60 without other use are needed.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-025
Night and short-term stores of pyrotechnic articles: RF1 containers with 5 or 10 m distance or an EI 60 screen wall
The day's stock from outdoor sales is kept outside opening hours in storage rooms under 11.2.1 to 11.2.5. Fireworks of categories 1 to 3 may be stored up to 1,000 kg gross in free-standing, dedicated RF1 containers.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-026
Sale of pyrotechnic articles in buildings: not in basements, stock at most 30 kg, sales stand not at escape routes
The person responsible for sales oversees the display area from their workplace; within 2 m of the stand smoking is banned with a clearly visible sign, and a portable extinguisher (water, spray or air foam) is ready.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-027
Outdoor sale of pyrotechnic articles: day's stock, at most 300 kg, 5 m to facades and escape exits
Outdoors the stock does not exceed the day's need; outside opening hours it is kept in the night store. At most 300 kg gross are at the sales stand.
Fire protection directive 26-15 Hazardous substances
violation
VKF-26-15-028
Fireworks: not inside buildings; stage pyrotechnics only in designated areas, stock at most 50 kg in a room EI 30
Fireworks for entertainment must not be set off inside buildings and installations; category 4 is reserved for commercial use by qualified persons.
Fire protection directive 26-15 Hazardous substances
violation
WBS-2015-001
Net living area meets the WBS minimum fit-out
The net living floor area of a dwelling (walkable floor areas from 1.50 m room height, WBS glossary) reaches at least the Grundausstattung value for the room count: 30 / 45 / 60 / 80 / 100 / 120 / 140 m² for 1 to 7 rooms. Sum the net areas of all spaces that share the same UsageUnitReference.
Housing evaluation system WBS
violation
WBS-2015-002
Rooms meet the WBS minimum areas
Habitable rooms of a dwelling meet the Grundausstattung minima: main rooms at least 14 m², other rooms at least 10 m² (WBS 2015 annex). Additional area offers (bays, niches, walkable zones) count toward K16 but do not replace the room minima.
Housing evaluation system WBS
violation
WBS-2015-003
Rooms allow varied furnishing per the WBS area module
Habitable rooms provide enough clear floor area and sensible door and window positions so the WBS area module for varied furnishing (living and sleeping without fixed use) fits. Assessment follows lead furniture such as sofa and table zones alongside Grundausstattung minima.
Housing evaluation system WBS
violation
WBS-2015-004
Rooms provide WBS-compliant bed positions
Each room allows at least one bed position per the WBS bed module: single 1.00 × 2.00 m or double 1.80 × 2.00 m with 0.60 m side clearances and free door swing. How many positions fit per room follows the layout and Grundausstattung.
Housing evaluation system WBS
violation
WBS-2015-005
Kitchen and dining areas meet the WBS Grundausstattung
The dwelling kitchen and dining zone allow the Grundausstattung: kitchen run in 0.60 m modules with an operating band, table module with chair zone by size (e.g. 1.6 × 1.6 m for 1 room up to 4.2 × 2.7 m for 7 rooms), and passage widths of at least 0.90 m.
Housing evaluation system WBS
violation
WBS-2015-006
Sanitary rooms meet WBS count and accessibility
The dwelling provides the sanitary rooms from Grundausstattung (1 to 3 rooms by apartment size, at least 3.8 m² per sanitary module in planning). At least one sanitary room is usable without barriers per accessibility building requirements (SIA 500, paraphrased).
Housing evaluation system WBS
violation
WBS-2015-007
Storage and kitchen areas provide WBS wardrobe modules
Storage and kitchen zones provide additional wardrobe modules from Grundausstattung (2 to 7 modules by room count, wardrobe module 0.60 × 0.60 × 1.80 m with 0.90 m front service clearance). Not yet checkable as SHACL: module count and footprints per dwelling unit and service zones are not aggregated quantities yet.
Housing evaluation system WBS
violation
WBS-2015-008
Apartment layout is adaptable after completion
Non-load-bearing interior walls of the dwelling are planned so they can be removed or added later to enable adaptable layouts. Assessment covers partitions between living spaces, not the load-bearing core.
Housing evaluation system WBS
violation
WBS-2015-009
Dwelling has private outdoor area per WBS
The dwelling has privately usable outdoor areas (balcony, terrace, garden, loggia) at least at Grundausstattung levels by room count (3 to 6 m²). Sum outdoor areas tied to the same UsageUnitReference.
Housing evaluation system WBS
violation
WBS-2015-010
Transitions between living space and outdoors are high quality
Transitions between living spaces and the private outdoor area (doors, windows, sliders, level changes, weather protection) enable comfortable, safe indoor-outdoor use without disruptive barriers. Thresholds, paths, and accesses match how the outdoor area is used.
Housing evaluation system WBS
violation
WBS-2015-011
Private storage rooms outside the dwelling are assigned
Private storage rooms outside the net dwelling floor area are clearly assigned to the dwelling unit (cellar, attic, locker), in line with Grundausstattung storage areas. Check assignment and usability via the same UsageUnitReference.
Housing evaluation system WBS
violation