Rule Fire protection directive 14-15 Use of building materials

Horizontal escape routes: reaction to fire of linings

VKF-14-15-011 pragmaticBIM.ch/vkf-14-15-011

In horizontal escape routes of low and medium-height buildings, wall and ceiling linings and classified systems are made of RF1 materials with a structural concept and of RF2 with an extinguishing-system concept; stretched ceilings are RF1 or RF2, one group lower where more than 5 m above walkable areas.

Description

Floor coverings are RF3. Fire-resistant walls, floors and columns in accommodation are made of RF1. Where there is no fire-rated closure between a horizontal and a vertical escape route, the requirements of vertical escape routes apply. High-rise buildings require RF1. Not yet checkable: the model does not carry the reaction-to-fire group (RF1 - RF4, cr) of materials.

Source

VKF-Brandschutzrichtlinie 14-15 Verwendung von Baustoffen (2015) (p. 10)

More rules for Fire protection directive 14-15 Use of building materials