Rule Fire protection directive 26-15 Hazardous substances

Outdoor sale of pyrotechnic articles: day's stock, at most 300 kg, 5 m to facades and escape exits

VKF-26-15-027 pragmaticBIM.ch/vkf-26-15-027

Outdoors the stock does not exceed the day's need; outside opening hours it is kept in the night store. At most 300 kg gross are at the sales stand.

Description

To facades without fire resistance a distance of at least 5 m applies, otherwise protective measures are needed (e.g. covers of at least EI 60). The goods are protected from sunlight, lens effects and heat radiation from lamps and heaters; plastic film covers are not allowed. Near hazardous substances (e.g. petrol stations) sale is allowed only with the fire protection authority's consent and special measures (e.g. 15 m to pumps). In shops under 200 m² sale in the shop window area is allowed. At least 5 m to escape exits must be kept. Not yet checkable: the model does not show category, gross mass, storage type and sales area of pyrotechnic articles.

Source

VKF-Brandschutzrichtlinie 26-15 Gefährliche Stoffe (2015) (p. 17)

More rules for Fire protection directive 26-15 Hazardous substances

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel