Rule Fire protection directive 26-15 Hazardous substances
Outdoor sale of pyrotechnic articles: day's stock, at most 300 kg, 5 m to facades and escape exits
VKF-26-15-027
pragmaticBIM.ch/vkf-26-15-027
Outdoors the stock does not exceed the day's need; outside opening hours it is kept in the night store. At most 300 kg gross are at the sales stand.
Description
To facades without fire resistance a distance of at least 5 m applies, otherwise protective measures are needed (e.g. covers of at least EI 60). The goods are protected from sunlight, lens effects and heat radiation from lamps and heaters; plastic film covers are not allowed. Near hazardous substances (e.g. petrol stations) sale is allowed only with the fire protection authority's consent and special measures (e.g. 15 m to pumps). In shops under 200 m² sale in the shop window area is allowed. At least 5 m to escape exits must be kept. Not yet checkable: the model does not show category, gross mass, storage type and sales area of pyrotechnic articles.
Source
VKF-Brandschutzrichtlinie 26-15 Gefährliche Stoffe (2015) (p. 17)
More rules for Fire protection directive 26-15 Hazardous substances
-
VKF-26-15-001
Hazardous substances from 100 kg: GHS classification, protection by type and quantity, fire protection concept before construction
The directive covers storage and handling of hazardous substances and preparations from 100 kg, unless other quantities are named. Substances are classified under the GHS, pyrotechnics under explosives law; diesel and heating oil count as combustible without classification.
-
VKF-26-15-002
No hazardous substances in escape routes or in front of exits; on-site overview, instruction, adaptation on change
Hazardous substances must not be kept in passages or drive-throughs, in horizontal or vertical escape routes, or in front of entrances and exits.
-
VKF-26-15-028
Fireworks: not inside buildings; stage pyrotechnics only in designated areas, stock at most 50 kg in a room EI 30
Fireworks for entertainment must not be set off inside buildings and installations; category 4 is reserved for commercial use by qualified persons.