Rule Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments

Structure in basements at least R 60

VKF-15-15-001 pragmaticBIM.ch/vkf-15-15-001

Load-bearing elements below ground need the same fire resistance as the structure of the storeys above, and in any case R 60. Single-family houses including their basement and buildings of small dimensions are exempt.

Description

The check covers load-bearing walls, slabs (without base slab), columns and beams on storeys below ±0.00.

Source

VKF-Brandschutzrichtlinie 15-15 Brandschutzabstände, Tragwerke, Brandabschnitte (2015) (p. 8)

More rules for Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments