Rule Fire protection directive 16-15 Escape and rescue routes
Buildings with small dimensions: 35 m escape route, narrower stairs
VKF-16-15-018
pragmaticBIM.ch/vkf-16-15-018
In buildings with small dimensions the escape route to a safe place outside is at most 35 m and may lead through several rooms within the use unit.
Description
Stairs serving several use units may be adapted for housing, office, school, trade and agriculture: straight stairs 0.9 m wide, winding stairs 1.2 m wide with an inner tread width of at least 0.1 m. For stairs within the use unit the use-specific requirements apply. Not yet checkable: whether a building counts as small and the flight width of stairs are missing in the model.
Source
VKF-Brandschutzrichtlinie 16-15 Flucht- und Rettungswege (2015) (p. 8)
More rules for Fire protection directive 16-15 Escape and rescue routes
-
VKF-16-15-019
Housing: relaxations for separations, stairs and doors
In residential buildings of low and medium height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes between vertical ones are subdivided with fire resistance, and they match the vertical ones in...
-
VKF-16-15-020
Office, trade and industry: relaxations and door dimensions
In office buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...
-
VKF-16-15-021
Schools and day-care centres: relaxations and short routes
In school buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...