Rule Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments

High-rise buildings: no inspection openings in safety stairwells, limit fire spread at the slab edge

VKF-15-15-022 pragmaticBIM.ch/vkf-15-15-022

In high-rise buildings, measures against fire spread are taken at every storey where the floor slab meets the external wall; they are not needed where full extinguishing-system protection is provided. Inspection openings of installation shafts are not located in safety stairwells.

Description

Not yet checkable: the model shows neither the fire-spread barriers at the slab edge nor the location of inspection openings.

Source

VKF-Brandschutzrichtlinie 15-15 Brandschutzabstände, Tragwerke, Brandabschnitte (2015) (p. 16)

More rules for Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments