Rule SIA 181 Sound insulation in buildings
Airborne sound insulation meets the requirement
SIA-181-001
pragmaticBIM.ch/sia-181-001
The verified airborne sound insulation of a wall, slab, door or exterior element reaches at least the required value. The acoustic consultant sets the requirement under SIA 181: between rooms from the room pair and the requirement level, for exterior elements from the exterior noise and the noise sensitivity.
Description
The check covers elements that carry both a requirement and a verified value; a missing verification is not a finding of this rule.
Source
SIA 181:2020 Schallschutz im Hochbau
More rules for SIA 181 Sound insulation in buildings
-
SIA-181-002
Impact sound level at most the permitted value
The verified impact sound level in the room below a slab does not exceed the maximum permitted value. The acoustic consultant sets the maximum under SIA 181 from the room pair and the requirement level.
-
SIA-181-003
Separating elements between usage units carry a sound insulation requirement
Walls, slabs and doors between rooms of different usage units, or between a usage unit and a room outside it such as the stairwell, need an airborne sound insulation requirement under SIA 181. Without a requirement neither the acoustic verification nor the check of the elements is possible.
-
SIA-181-004
Rooms next to other usage units carry noise load and noise sensitivity
A room of a usage unit that adjoins a room outside its unit through a wall, slab or door needs a noise load and a noise sensitivity. Under SIA 181 the requirement of the separating element depends on both values of the room pair; if one is missing, it cannot be derived.