Sale of pyrotechnic articles in buildings: not in basements, stock at most 30 kg, sales stand not at escape routes

VKF-26-15-026 pragmaticBIM.ch/vkf-26-15-026

The person responsible for sales oversees the display area from their workplace; within 2 m of the stand smoking is banned with a clearly visible sign, and a portable extinguisher (water, spray or air foam) is ready.

Description

In buildings, sale is not allowed in single-storey sales rooms over 1,000 m², in multi-storey, openly connected shops and in basement storeys. Stock in the sales room is at most 30 kg gross, kept apart from other flammable substances in closed containers inaccessible to customers. The stand is not placed in front of entrances and exits or escape routes. In shop windows only marked dummies are allowed. Not yet checkable: the model does not show category, gross mass, storage type and sales area of pyrotechnic articles.

Source

VKF-Brandschutzrichtlinie 26-15 Gefährliche Stoffe (2015) (p. 16)