Rule Fire protection directive 14-15 Use of building materials

Vertical escape routes: reaction to fire of linings and structures

VKF-14-15-010 pragmaticBIM.ch/vkf-14-15-010

In vertical escape routes (stairwells) of low and medium-height buildings with a structural concept, walls and floors with fire resistance, wall and ceiling linings, classified systems, stretched ceilings and stair and landing structures are made of RF1 materials; floor coverings are at least RF2.

Description

In low buildings the next lower group is allowed for floor coverings and stairs. Walls and floors without fire resistance and insulation layers are clad with RF1 fire protection boards of 30 minutes where they are combustible. High-rise buildings require RF1 in all escape routes. Not yet checkable: the model does not carry the reaction-to-fire group (RF1 - RF4, cr) of materials.

Source

VKF-Brandschutzrichtlinie 14-15 Verwendung von Baustoffen (2015) (p. 10)