Rule Fire protection directive 14-15 Use of building materials

Other interior rooms: minimum reaction-to-fire requirements

VKF-14-15-013 pragmaticBIM.ch/vkf-14-15-013

In interior rooms outside escape routes, RF3 materials generally suffice in low and medium-height buildings. Exceptions: in accommodation and rooms with large occupancy, stretched ceilings are RF1 with a structural concept and RF2 with an extinguishing-system concept.

Description

Walls and floors without fire-resistance requirement may be RF3. In high-rise buildings, walls and floors with fire resistance and classified systems in accommodation and rooms with large occupancy require RF1 under the structural concept. Fixed seating in rooms with large occupancy is made of RF2. Not yet checkable: the model does not carry the reaction-to-fire group (RF1 - RF4, cr) of materials.

Source

VKF-Brandschutzrichtlinie 14-15 Verwendung von Baustoffen (2015) (p. 10)