Rule Fire protection directive 14-15 Use of building materials
Other interior rooms: minimum reaction-to-fire requirements
VKF-14-15-013
pragmaticBIM.ch/vkf-14-15-013
In interior rooms outside escape routes, RF3 materials generally suffice in low and medium-height buildings. Exceptions: in accommodation and rooms with large occupancy, stretched ceilings are RF1 with a structural concept and RF2 with an extinguishing-system concept.
Description
Walls and floors without fire-resistance requirement may be RF3. In high-rise buildings, walls and floors with fire resistance and classified systems in accommodation and rooms with large occupancy require RF1 under the structural concept. Fixed seating in rooms with large occupancy is made of RF2. Not yet checkable: the model does not carry the reaction-to-fire group (RF1 - RF4, cr) of materials.
Source
VKF-Brandschutzrichtlinie 14-15 Verwendung von Baustoffen (2015) (p. 10)
More rules for Fire protection directive 14-15 Use of building materials
-
VKF-14-15-001
High-rise buildings: external wall and cladding system made of RF1 materials
The external wall and the external wall cladding system of high-rise buildings are made of RF1 materials. Exceptions are plastic anchors, point back-anchorages of insulation and components of negligible area such as joints or seals.
-
VKF-14-15-014
Interior fit-out: thin coatings and linear substructures where RF1/RF2 is required
Where RF1 is required for interior walls, floors and ceilings, combustible coatings such as paint, wallpaper or veneer up to 1.5 mm thick are allowed on the room side. Where RF1 or RF2 is required, linear substructures such as battens may be RF3, provided the visible side has a closed layer of the required group.
-
VKF-14-15-015
Evacuation rooms, airlocks and anterooms: assignment to escape routes
For materials, evacuation rooms count as vertical escape routes, except patient rooms and horizontal escape routes in accommodation. Airlocks count as vertical escape routes, anterooms as horizontal ones.