Rule Fire protection directive 16-15 Escape and rescue routes
Housing: relaxations for separations, stairs and doors
VKF-16-15-019
pragmaticBIM.ch/vkf-16-15-019
In residential buildings of low and medium height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes between vertical ones are subdivided with fire resistance, and they match the vertical ones in...
Description
In residential buildings of low and medium height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes between vertical ones are subdivided with fire resistance, and they match the vertical ones in material, fire resistance and risk of activation. For low buildings, winding stairs 1.2 m wide with an inner tread width of at least 0.1 m are allowed. If a stair serves at most one upper and one lower storey, straight stairs of 0.9 m suffice. Within the dwelling there are no stair requirements, and doors inside the dwelling are exempt from the width and swing rules. Dwelling entrance doors need not open in the escape direction; building entrance doors need not either if they serve at most 10 dwellings. The escape route may lead through several rooms within the use unit. Not yet checkable: building height class, dwelling units and fire separations are often missing in the model.
Source
VKF-Brandschutzrichtlinie 16-15 Flucht- und Rettungswege (2015) (p. 9)
More rules for Fire protection directive 16-15 Escape and rescue routes
-
VKF-16-15-020
Office, trade and industry: relaxations and door dimensions
In office buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...
-
VKF-16-15-021
Schools and day-care centres: relaxations and short routes
In school buildings of low height, fire separations between horizontal and vertical escape routes may be omitted if the floor area per vertical escape route is at most 900 m², the horizontal escape routes are subdivided with fire resistance and match the vertical ones in material, fire resistance and risk of...
-
VKF-16-15-022
Stairs and ramps with large occupancy: width, steps, gradient
For shops and rooms with large occupancy, the total width of stair flights and landings follows the widest exit of the connected storeys. Stairs wider than 2.4 m are divided by handrails.