Rule Fire protection directive 16-15 Escape and rescue routes

Car parks: airlocks or forecourts for compartments above 1200 m²

VKF-16-15-027 pragmaticBIM.ch/vkf-16-15-027

If exits of a parking area lead into a vertical escape route and the fire compartment area exceeds 1200 m², fire-resistant airlocks or forecourts are to be provided. The fire resistance of the airlocks matches that of the load-bearing structure but is at least EI 30.

Description

The airlock doors to the vertical or horizontal escape route are to be self-closing with E 30. The appendix notes that locked accesses from car parks to vertical escape routes (e.g. in residential buildings) do not count as escape routes. Not yet checkable: fire compartment areas and airlocks are not identified in the model.

Source

VKF-Brandschutzrichtlinie 16-15 Flucht- und Rettungswege (2015) (p. 12)