Rule Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
Fire separation distance between buildings
VKF-15-15-009
pragmaticBIM.ch/vkf-15-15-009
Between neighbouring buildings, measured facade to facade: 5 m if both facades are RF1 materials on the outside; 7.5 m if one is combustible on the outside; 10 m if both are.
Description
Between single-family houses, low buildings and medium-height buildings with external walls of at least 30 minutes fire resistance the values shrink to 4 m, 5 m and 6 m. Roof overhangs or elements projecting more than 1 m increase the distance by the excess. Not yet checkable: the conversion does not compute distances to neighbouring buildings.
Source
VKF-Brandschutzrichtlinie 15-15 Brandschutzabstände, Tragwerke, Brandabschnitte (2015) (p. 5)
More rules for Fire protection directive 15-15 Fire safety distances, load-bearing structures, fire compartments
-
VKF-15-15-010
Office buildings: fire compartment at most 3600 m²
In office buildings a fire compartment covers at most 3600 m² without special proof. All storeys connected without fire resistance count together.
-
VKF-15-15-011
Penetrations through compartment components: firestop of at least 30 minutes
Openings and service penetrations in walls and floors that form fire compartments are closed with fire resistance; the firestop holds for at least 30 minutes. Allowing for thermal expansion, the recess is either filled tightly with RF1 materials or closed with a VKF-recognized firestop system rated EI 30.
-
VKF-15-15-012
Pipes through compartment components: recognized firestop system
Where pipes pass through components that form fire compartments, a VKF-recognized firestop system is used, e.g. a fire collar.