School buildings: fire compartment at most 3600 m², special rooms separate

VKF-15-15-019 pragmaticBIM.ch/vkf-15-15-019

School operations and associated uses, as well as the gymnasium with its ancillary rooms, may each be combined in one fire compartment. Without special proof the contiguous compartment area is at most 3600 m²; it includes all storeys connected without fire resistance.

Description

Special rooms such as school kitchen, cafeteria, workshops and laboratories form their own fire compartments. Not yet checkable: the model does not identify fire compartments.

Source

VKF-Brandschutzrichtlinie 15-15 Brandschutzabstände, Tragwerke, Brandabschnitte (2015) (p. 15)