pragmaticBIM Reference
Elements
Elements are the building components and objects a model has to contain. Each element names its IFC entity and the attributes the use cases ask for.
PROJECT
Project
Establishes the shared organizational frame of reference so that discipline models and their content can be assigned unambiguously to the same construction project.
Architecture
IfcProject
SITE
Planning perimeter
Defines the shared project area so that buildings, property references, and external works can be coordinated consistently in space.
Architecture
IfcSite
BUILDING
Building
Structures the construction project into clearly identifiable building volumes so that discipline models, storeys, and evaluations can be coordinated by building.
Architecture
IfcBuilding
STOREY
Storey
Establishes the shared vertical structure so that spaces and components can be assigned to the same building level across all discipline models.
Architecture
IfcBuildingStorey
SURVEY-REF
Survey reference point
Provides a binding position and height reference so that discipline models align correctly and can be set out accurately on site.
Architecture
IfcBuildingElementProxy
SPACE-GROSS
Gross volumes
Provides a consistent basis for massing studies, area and volume evaluations, and urban design decisions.
Architecture
IfcSpace
SPACE-INT
Interior spaces
Links the room programme, area verification, and discipline planning so that use, sizing, and technical requirements can be coordinated for each space.
Architecture
IfcSpace
SPACE-EXT
Exterior spaces
Makes usable exterior areas measurable for area verification, use planning, and coordination between the building and its surroundings.
Architecture
IfcSpace
SPACE-ELEVATOR
Lift
Enables the occupied area to be assigned by storey so that area verification can be maintained correctly.
Architecture
IfcSpace
SPACE-AIR
Air spaces
Prevents non-occupiable volumes from being counted as floor area while providing a spatial reference for building services.
Architecture
IfcSpace
SPACE-PARK
Parking spaces
Enables traceable parking verification and reliable area and traffic planning from the building design phase onward.
Architecture
IfcSpace
SPACE-VORSATZ
Wall lining (usable space)
Makes space and floor-area loss verifiable early so that rooms, especially sanitary spaces, can be sized adequately.
Architecture
IfcSpace
ARC-WALL-EXT
Exterior wall
Exterior walls provide the basis for area and quantity take-off, building physics, and facade coordination.
Architecture
IfcWall
ARC-SLAB-BALCONY
Balcony
Makes exterior space, the structural concept, and the building envelope jointly verifiable early on and supports reliable permitting and cost decisions.
Architecture
IfcSlab
ARC-SLAB-BASE
Base slab
Makes the building support and load transfer into the ground spatially verifiable early and provides design certainty for basements, waterproofing, and excavation.
Architecture
IfcSlab
ARC-SLAB-FLOOR
Floor slab
Defines the load-bearing separation between storeys early and provides design certainty for room heights, structure, and building services.
Architecture
IfcSlab
ARC-ROOF-FLAT
Flat roof
Makes the structural concept and building enclosure spatially verifiable early and provides design certainty for levels, build-ups, and permitting.
Architecture
IfcSlab
ARC-FOOTING
Footing
Makes the space and location required to transfer loads into the ground verifiable early and prevents conflicts with basements, services, and excavation.
Architecture
IfcFooting
ARC-WALL-INT
Non-load-bearing interior wall
Makes the spatial layout reliably verifiable early on and provides the basis for fire, acoustic, and interior-fit-out coordination.
Architecture
IfcWall
ARC-WALL-INT-LB
Load-bearing interior wall
Makes load transfer and space separation jointly verifiable early on and provides a reliable basis for structural, fire, and acoustic coordination.
Architecture
IfcWall
ARC-COLUMN
Column
Makes point load transfers spatially verifiable early and prevents conflicts with the spatial layout, facade, and building services.
Architecture
IfcColumn
ARC-ROOF-PITCH
Pitched roof
Makes the roof form and structural concept spatially verifiable early on and supports reliable permitting and coordination decisions.
Architecture
IfcRoof
ARC-STAIR
Stair
Rough stair geometry for design, coordination, and quantity take-off.
Architecture
IfcStairFlight
ARC-BEAM
Beam / girder
Makes load-transfer zones visible early and prevents conflicts between the structure, spatial concept, and building services.
Architecture
IfcBeam
ARC-RAILING
Fall protection / railing
Simplified geometry for spatial planning and assessment of permanent and temporary fall protection.
Architecture
IfcRailing
ARC-WINDOW-EXT
Exterior window
Ensures daylight, ventilation, and views and provides a verifiable basis for facade and building-physics design.
Architecture
IfcWindow
ARC-DOOR-EXT
Exterior door
Ensures functional building access and provides the basis for escape-route, facade, and building-physics design.
Architecture
IfcDoor
ARC-OPENING-VOID
Opening / recess (architecture)
Secures the required routes for services and installations and prevents uncoordinated penetrations between architecture, structure, and building services.
Architecture
IfcOpeningElement
ARC-WINDOW-INT
Interior window
Ensures daylight transfer between interior spaces and provides a verifiable basis for spatial and acoustic design.
Architecture
IfcWindow
ARC-DOOR-INT
Interior door / inspection hatch
Ensures functional connections between spaces and provides the basis for escape-route, fire, and acoustic design.
Architecture
IfcDoor
ARC-SHADING
Shading device
Makes external sun protection visible in the model so location, type, and shading are recorded for facade planning and thermal simulation.
Architecture
IfcShadingDevice
ARC-FIRE-ACOUSTIC-SEAL
Firestop / acoustic seal
Separates the installed seal from the opening and makes its type, performance, and quantity verifiable for tendering, construction, and operation.
Architecture
IfcBuildingElementProxy
ARC-CEILING
Suspended ceiling
Ensures coordinated room heights, ceiling design, and building services.
Architecture
IfcCovering
ARC-FLOOR-COV
Interior floor build-up
Provides a reliable basis for level coordination, joint design, tendering, and quantity take-off for interior finishes. Modelled in every room from tendering on; before that and in operation, the floor finish sits on the interior space.
Architecture
IfcCovering
ARC-FLOOR-COV-EXT
Exterior floor covering
Makes exterior finishes verifiable in detail design for quantities, joints, and tendering. Early planning without a modelled covering: FloorCovering (AOF) on the exterior space.
Architecture
IfcCovering
ARC-WALL-CLAD-EXT
Facade cladding
Enables separate design and quantity take-off of the facade surface and improves coordination with connections and openings.
Architecture
IfcCovering
ARC-ROOF-DRAIN
Tapered insulation / roof build-up
Shows early how much build-up height the roof and balcony fall requires. The building height is then fixed for the permit, and pipes in the foundation can be connected to the outlets.
Architecture
IfcCovering
ARC-ROOF-OVERFLOW
Emergency overflow
Shows early where and at what level water leaves the roof when outlets are blocked, so the parapet, facade, waterproofing upstand, and structural load assumptions can be coordinated.
Architecture
IfcBuildingElementProxy
FURN
Furniture
Reveals early whether spaces can actually be furnished for their intended use and are adequately sized.
Architecture
IfcFurniture
ARC-FURN-BUILTIN
Built-in furniture / kitchen
Shows early how much space the kitchen and built-in cabinets need and where the connections sit. Shop and installation design can check dimensions and connections against this.
Architecture
IfcFurniture
ARC-WALL-CLAD
Interior wall cladding
Enables room-specific design and quantity take-off of surface finishes for tendering and interior-fit-out coordination.
Architecture
IfcCovering
ARC-DRYWALL-REINF
Drywall reinforcement zone
Makes required fixing support spatially checkable before tendering and construction and prevents subsequent daywork.
Architecture
IfcBuildingElementProxy
LAN-TREE
Tree
Makes decisions on protection, removal, and new planting spatially verifiable so that the building and external works account for the tree inventory.
Architecture
IfcGeographicElement
SURVEY-SURFACE
Surface geometry
Provides existing and designed terrain so that connections to the building and earth quantities can be planned in coordination.
Architecture
IfcGeographicElement
ARC-PARCEL
Building-law parcels
Shows early which cadastral parcels the project affects and supports alignment of the planning perimeter and permitting process.
Architecture
IfcBuildingElementProxy
LAN-HUMUS
Topsoil
Makes topsoil quantities verifiable early for cost, so that stripping, reinstatement, and surplus do not appear only at tender.
Architecture
IfcGeographicElement
ARC-UMG-NEIGHBOR
Surrounding buildings
Represents neighbouring buildings as simple volumes so objection-relevant effects (shadow, views, setbacks) can be checked and documented in the stakeholder dialogue.
Architecture
IfcBuildingElementProxy
LAN-RETENTION
Retention volume
Makes retention volume assignable to catchments and the sizing against heavy rain traceable.
Architecture
IfcBuildingElementProxy
ARC-SITE-LOG
Site setup object
Makes the space requirements and sequence of site logistics alignable early and prevents conflicts during construction.
Architecture
IfcBuildingElementProxy
ARC-DET-REF
Detail reference
Makes it spatially verifiable where standard details apply and reveals missing or conflicting detail assignments early.
Architecture
IfcBuildingElementProxy
ARC-DEC-VOL
Decision volume
Makes it spatially verifiable where a decision applies and whether it is still open, approved, or superseded.
Architecture
IfcBuildingElementProxy
ARC-INSTALL-PATH
Installation access path
Ensures large equipment can be transported to its installation location without clashes.
Architecture
IfcBuildingElementProxy
ARC-COORD-ZONE
Coordination zone
Clearly assigns spatial review areas to coordination meetings and prevents unclear responsibilities.
Architecture
IfcBuildingElementProxy
ARC-CONSTRAINT
Planning constraint
Makes external requirements spatially verifiable from an early stage and supports quality assurance when checking the design against protection, hazard, and permitting requirements.
Architecture
IfcBuildingElementProxy
ARC-MAINT-SPACE
Maintenance space
Ensures plant remains permanently accessible and can be maintained without spatial conflicts.
Architecture
IfcBuildingElementProxy
ARC-MOVEMENT-CLEARANCE
Movement clearance
Makes the areas that must remain clear for accessibility spatially verifiable so conflicts with building elements and furniture are found before the permit submission.
Architecture
IfcBuildingElementProxy
ARC-TURN-RAD
Turning radius
Demonstrates that vehicles can safely use the planned access routes and manoeuvring areas.
Architecture
IfcBuildingElementProxy
ARC-UMBAU-PER
Alteration area
Makes planned and completed alterations spatially and chronologically traceable in the overall model.
Architecture
IfcBuildingElementProxy
ARC-DEVICE-SPACE
Device space
Reserves space early for devices that drive room size, structure or connections, so special rooms can be agreed with users before devices are chosen.
Architecture
IfcBuildingElementProxy
MEP-PROV-VOID
Provision for void
Reserves penetrations in time so structure and building services can be coordinated without later core drilling.
MEP
IfcBuildingElementProxy
MEP-SCH-PIPE
Pipe (schematic)
Reserves main pipework routes in the initial phase and reduces later clashes.
MEP
IfcPipeSegment
MEP-SCH-DUCT
Duct (schematic)
Reserves main ventilation routes in the initial phase and reduces later clashes.
MEP
IfcDuctSegment
MEP-SCH-TRAY
Cable tray (schematic)
Reserves main electrical routes in the initial phase and reduces later clashes.
MEP
IfcCableCarrierSegment
MEP-SCH-EQUIP
Plant space (schematic)
Reserves sufficient plant-room space in the initial phase and prevents conflicts with other uses.
MEP
IfcBuildingElementProxy
MEP-DOWNPIPE
Downpipe
Secures roof and balcony drainage by coordinating routes, connections, and slab penetrations.
MEP
IfcPipeSegment
MEP-CHILLER
Chiller
Secures cooling supply by coordinating capacity, plant footprint, and service connections early.
MEP
IfcChiller
MEP-COOL-TOWER
Cooling tower / free cooler
Secures heat rejection by coordinating capacity, location, structure, acoustics, and water management.
MEP
IfcCoolingTower
MEP-ELEC-GEN
Backup generator
Secures standby power by coordinating capacity, location, fuel supply, and exhaust routing.
MEP
IfcElectricGenerator
MEP-ELEC-DIST
Electrical distribution board
Represents the distribution hierarchy so loads, feeders, plant space, and accessibility can be coordinated.
MEP
IfcElectricDistributionBoard
MEP-TRANSFORMER
Transformer
Secures the required voltage level by coordinating load, plant space, cooling, and protection requirements.
MEP
IfcTransformer
MEP-UPS
Uninterruptible power supply
Secures critical loads by coordinating autonomy, loads, plant space, and cooling.
MEP
IfcElectricFlowStorageDevice
MEP-BOILER
Boiler / water heater
Secures heat supply by coordinating capacity, plant footprint, flue route, and service connections early.
MEP
IfcBoiler
MEP-HEAT-EX
District heat substation
Clarifies thermal system separation so substation capacity, connections, and space requirements can be coordinated.
MEP
IfcHeatExchanger
MEP-COMPRESSOR
Compressed air compressor
Secures compressed-air supply by coordinating capacity, location, acoustic protection, and connections.
MEP
IfcCompressor
MEP-GAS-REG
Gas pressure regulator
Clarifies the gas supply interface so pressure level, metering, safety distances, and pipe connections can be coordinated.
MEP
IfcFlowMeter
MEP-FAN
Fan
Secures the required airflow by coordinating duty, duct connections, acoustic protection, and maintenance access.
MEP
IfcFan
MEP-TANK
Tank / separator
Secures the required storage volume by coordinating location, structure, connections, and maintenance access.
MEP
IfcTank
MEP-PUMP
Pump
Secures flow and pressure by coordinating duty, connections, location, and maintenance access.
MEP
IfcPump
MEP-UNITARY
Unitary equipment / monoblock
Secures compact plant operation by coordinating footprint, service connections, and maintenance zones together.
MEP
IfcUnitaryEquipment
MEP-COMMS
Communications appliance
Fixes communication device locations so coverage, connectivity, power supply, and finishes can be coordinated.
MEP
IfcCommunicationsAppliance
MEP-COOL-BEAM
Chilled ceiling / beam
Secures room conditioning and coordinates output, water connections, condensation risk, and ceiling layout.
MEP
IfcCooledBeam
MEP-SPACE-HEATER
Radiator
Secures room heat delivery by coordinating output, connections, placement, and clearances.
MEP
IfcSpaceHeater
MEP-AIR-TERM
Air terminal / grille
Enables air-distribution verification and coordination with ceiling layout and occupied zones.
MEP
IfcAirTerminal
MEP-AIR-BOX
Air terminal box
Enables demand-based airflow control and secures installation and maintenance space above the ceiling.
MEP
IfcAirTerminalBox
MEP-LIGHT
Light fixture
Enables lighting verification and coordination of ceiling layout, power supply, and maintenance access.
MEP
IfcLightFixture
MEP-OUTLET
Socket / data outlet
Fixes connection points so use, service routes, and finishes can be coordinated.
MEP
IfcOutlet
MEP-SWITCH
Switch
Fixes control and switching points so electrical function, finishes, and user access can be coordinated.
MEP
IfcSwitchingDevice
MEP-DAMPER
Damper
Fixes air isolation and control points so airflow, fire safety, and maintenance access can be coordinated.
MEP
IfcDamper
MEP-SANITARY
Sanitary terminal
Fixes sanitary fixtures so use, water connections, drainage, and space requirements can be coordinated.
MEP
IfcSanitaryTerminal
MEP-WASTE
Waste terminal
Fixes drainage points so falls, pipe routes, and sanitary fixtures can be coordinated.
MEP
IfcWasteTerminal
MEP-GAS-TERM
Gas outlet
Fixes gas draw-off points so pipe routes, isolation, and appliance connections can be coordinated.
MEP
IfcFlowTerminal
MEP-FIRE-TERM
Fire suppression terminal
Enables verification of fire-suppression coverage and coordination of the required clearances.
MEP
IfcFireSuppressionTerminal
MEP-VALVE
Valve / manifold
Fixes isolation and control points to support operation, hydraulic balancing, and maintenance.
MEP
IfcValve
MEP-ALARM
Smoke detector / alarm
Enables verification of fire detection coverage and coordinated placement with finishes and ceilings.
MEP
IfcAlarm
MEP-SENSOR
Sensor
Fixes measurement points so controls, monitoring, and accessibility can be coordinated.
MEP
IfcSensor
MEP-ACTUATOR
Actuator
Makes control functions coordinable so controls, power supply, and maintenance access are secured.
MEP
IfcActuator
STR-EXCL-ZONE
Exclusion zone
Keeps required structural volumes clear and prevents costly clashes with architecture and building services.
Structural engineering
IfcBuildingElementProxy
STR-OPENING-VOID
Opening / recess (structural)
Transfers approved voids into the structural model as binding information so that clashes are avoided and penetrations can be built as planned.
Structural engineering
IfcOpeningElement
STR-BEAM
Beam / girder detailed
Enables reliable coordination of load transfer, penetrations, and connections through to execution.
Structural engineering
IfcBeam
STR-COLUMN
Column detailed
Ensures coordinated load transfer and clash-free placement of adjacent components through to execution.
Structural engineering
IfcColumn
STR-FOOTING
Footing detailed
Provides a reliable basis for coordinating load transfer, excavation, and utility lines.
Structural engineering
IfcFooting
STR-WALL
Wall detailed
Enables reliable coordination of load transfer, openings, and connections through to execution.
Structural engineering
IfcWall
STR-SLAB-FLOOR
Floor slab detailed
Enables reliable coordination of load transfer, openings, and cast-in items through to execution.
Structural engineering
IfcSlab
STR-SLAB-BASE
Base slab detailed
Ensures coordinated planning of load transfer, waterproofing, and penetrations through to execution.
Structural engineering
IfcSlab
STR-SLAB-ROOF
Flat roof detailed
Ensures coordinated planning of load transfer, falls, roof build-up, and penetrations.
Structural engineering
IfcSlab
STR-STAIR
Stair detailed
Ensures early coordination of the structure, level transitions, and usable flight geometry.
Structural engineering
IfcStair
STR-RAMP
Ramp detailed
Ensures early coordination of the structure, level transitions, and required gradient.
Structural engineering
IfcRamp
STR-REBAR
Reinforcement
Provides unambiguous steel schedules and placing information to reduce execution errors.
Structural engineering
IfcReinforcingBar
STR-EDGE-STRIP
Edge strip
Ensures formwork terminations can be specified, coordinated, and executed unambiguously.
Structural engineering
IfcBuildingElementProxy
MEP-ESCAPE-SIGN
Escape sign
Makes exits and escape directions visible in the model so fire protection and electrical design can check marking, lighting type, and supply together.
Fire protection
IfcBuildingElementProxy