Rule Fire protection directive 16-15 Escape and rescue routes

Access balconies: open, made of RF1, leading to the vertical escape route

VKF-16-15-016 pragmaticBIM.ch/vkf-16-15-016

Access balconies lead to vertical escape routes and consist of RF1 materials; linear load-bearing members may be combustible. They are permanently open to the outside for at least half, with evenly distributed openings that cannot be closed.

Description

No fire resistance is required for doors and windows, and the horizontal escape route length still applies. If the access balcony leads to only one vertical escape route, its walking surfaces have 30 minutes of fire resistance and connect to the external wall with fire resistance; the external wall cladding consists of RF1. If it leads to vertical escape routes at both ends, the fire resistance requirements for the construction fall away and the cladding may be combustible. Not yet checkable: openness and walking surface build-up are not recorded in the model.

Source

VKF-Brandschutzrichtlinie 16-15 Flucht- und Rettungswege (2015) (p. 8)