Rule Fire protection directive 14-15 Use of building materials

Ventilated facades: recognized construction, substructure RF3, fixings RF2

VKF-14-15-006 pragmaticBIM.ch/vkf-14-15-006

Ventilated facades on medium-height buildings whose cladding or insulation in the ventilated cavity is combustible are VKF-recognized or equivalent constructions. On low and medium-height buildings, rod-shaped substructures made of RF3 materials suffice.

Description

Point fixings and back-anchorages inside the insulation are made of at least RF2 materials at all building heights. Not yet checkable: the model does not carry the reaction-to-fire group (RF1 - RF4, cr) of materials.

Source

VKF-Brandschutzrichtlinie 14-15 Verwendung von Baustoffen (2015) (p. 6)