Rule Fire protection directive 16-15 Escape and rescue routes

High-rise buildings: safety stairwells with airlocks

VKF-16-15-029 pragmaticBIM.ch/vkf-16-15-029

In high-rise buildings, storeys above ground are served by safety stairwells. These are vertical escape routes specially protected against the entry of smoke and fire (pressurized smoke control system).

Description

The roof must be accessible from a safety stairwell. Internal safety stairwells are entered on every storey through an airlock directly in front with a plan size of at least 1.2 m × 2.4 m, whose doors are self-closing. No airlock is needed where access is through forecourts or corridors permanently open to the outside. With a firefighters' lift, the airlock or forecourt in front of it must, according to the appendix, measure at least 2.4 m × 2.4 m. Not yet checkable: high-rise status, pressurization system and airlock dimensions are missing in the model.

Source

VKF-Brandschutzrichtlinie 16-15 Flucht- und Rettungswege (2015) (p. 13)

More rules for Fire protection directive 16-15 Escape and rescue routes

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel