Exterior floor covering
ARC-FLOOR-COV-EXT
pragmaticBIM.ch/arc-floor-cov-ext
Makes exterior finishes verifiable in detail design for quantities, joints, and tendering. Early planning without a modelled covering: FloorCovering (AOF) on the exterior space.
Description
- Modelled outdoor surfacing (paths, plazas, terraces, paved areas) according to the outdoor floor surface classification (AOF).
- Complements the space property FloorCovering once build-up and joints become relevant.
Modelling guidelines
- Model as one layer - split by finish type, not by individual space polygons.
- Set IsExternal=TRUE; carry Finish with an AOF name (leaf when the surface is known, otherwise the parent class).
- Do not model vegetation or retention here - those belong to landscape elements or space properties.
IFC entity
- IFC4
- IfcCovering
- IFC4.3
- IfcCovering
- IFC2x3
- IfcCovering
- Applicability rule
- entity_ifc4=IfcCovering AND PredefinedType=FLOORING AND IsExternal=TRUE
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Marks the exterior floor covering. Allowed values
|
+1 more |
| IsExternal Pset_CoveringCommon |
Marks an exterior floor covering. Allowed values
|
|
| Finish Pset_CoveringCommon |
Outdoor floor surface according to Abstract outdoor floor surfaces (AOF). Leaf name when the surface is known; otherwise the parent class. Allowed values
|
|
| Status Pset_CoveringCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
|
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| NetArea Qto_CoveringBaseQuantities · m² |
Net area of the modelled exterior floor covering. |
+1 more |
Related elements
-
ARC-WALL-CLAD-EXT
Facade cladding
Enables separate design and quantity take-off of the facade surface and improves coordination with connections and openings.
-
ARC-ROOF-DRAIN
Tapered insulation / roof build-up
Shows early how much build-up height the roof and balcony fall requires. The building height is then fixed for the permit, and pipes in the foundation can be connected to the outlets.
-
ARC-ROOF-OVERFLOW
Emergency overflow
Shows early where and at what level water leaves the roof when outlets are blocked, so the parapet, facade, waterproofing upstand, and structural load assumptions can be coordinated.