Chiller
MEP-CHILLER
pragmaticBIM.ch/mep-chiller
Secures cooling supply by coordinating capacity, plant footprint, and service connections early.
Description
- Chiller for building cooling.
- Chiller plant.
Modelling guidelines
- Model as an equipment object with size and location.
- Assign to the matching storey and technical or use zone.
IFC entity
- IFC4
- IfcChiller
- IFC4.3
- IfcChiller
- IFC2x3
- IfcEnergyConversionDevice
- Applicability rule
- entity_ifc4=IfcChiller
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Kind of equipment or terminal. Allowed values
|
|
| Tag |
Plant identification (AKS) to the client standard. Where no project-specific standard applies, we suggest |
|
| Status Pset_ChillerTypeCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| WarrantyEndDate Pset_Warranty |
Warranty end date - to be provided by the contractor. |
|
| DatasheetLink ePset_ProductData |
Link (URI) to the product datasheet. |
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
|
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from element type, medium, and BelowTerrain. Allowed values
|
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
Related elements
-
MEP-COOL-TOWER
Cooling tower / free cooler
Secures heat rejection by coordinating capacity, location, structure, acoustics, and water management.
-
MEP-ELEC-GEN
Backup generator
Secures standby power by coordinating capacity, location, fuel supply, and exhaust routing.
-
MEP-ELEC-DIST
Electrical distribution board
Represents the distribution hierarchy so loads, feeders, plant space, and accessibility can be coordinated.