Installation access path
ARC-INSTALL-PATH
pragmaticBIM.ch/arc-install-path
Ensures large equipment can be transported to its installation location without clashes.
Description
- Volume that must remain clear for transporting and bringing in large equipment or components.
- Used for coordination and verification, not for detailing individual building elements.
Modelling guidelines
- Model as a simplified proxy body; dimensions according to the required clearance.
- Assign to the matching storey; ObjectType = Einbringweg.
- Do not model building elements, equipment, or finishes inside the volume.
IFC entity
- IFC4
- IfcBuildingElementProxy
- IFC4.3
- IfcBuildingElementProxy
- IFC2x3
- IfcBuildingElementProxy
- Applicability rule
- {'de': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType=Einbringweg) OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType=Einbringweg)', 'fr': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Voie d\'apport") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Voie d\'apport")', 'it': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Percorso di trasporto") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Percorso di trasporto")', 'en': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Installation path") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Installation path")'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Installation access path designation. |
|
| PredefinedType |
Marks the proxy as a user-defined type. Allowed values
|
|
| ObjectType |
Kind of proxy element. Allowed values
|
Related elements
-
ARC-COORD-ZONE
Coordination zone
Clearly assigns spatial review areas to coordination meetings and prevents unclear responsibilities.
-
ARC-CONSTRAINT
Planning constraint
Makes external requirements spatially verifiable from an early stage and supports quality assurance when checking the design against protection, hazard, and permitting requirements.
-
ARC-MAINT-SPACE
Maintenance space
Ensures plant remains permanently accessible and can be maintained without spatial conflicts.