Opening / recess (structural)
STR-OPENING-VOID
pragmaticBIM.ch/str-opening-void
Transfers approved voids into the structural model as binding information so that clashes are avoided and penetrations can be built as planned.
Description
- Void in a load-bearing wall, slab, or other structural component for MEP penetrations and construction recesses.
- Governing for coordination, approval, and execution; replaces the MEP void request after approval.
Modelling guidelines
- Model as an opening element and assign it to the voided structural host; dimensions and location according to the approved request.
- Through opening as OPENING; one-sided or non-through recess as RECESS.
- Align Name and Reference with the MEP void request; name uniquely by storey and host component.
IFC entity
- IFC4
- IfcOpeningElement
- IFC4.3
- IfcOpeningElement
- IFC2x3
- IfcOpeningElement
- Applicability rule
- entity_ifc4=IfcOpeningElement OR entity_ifc2x3=IfcOpeningElement
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Opening designation for assignment to service, equipment, or MEP void request. |
|
| PredefinedType |
Marks the kind of opening. Allowed values
|
|
| Reference Pset_OpeningElementCommon |
Reference for unique identification of the opening in the coordination and structural models. |
+1 more |
| Status Pset_OpeningElementCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| OverallWidth ePset_OpeningDimensions · m |
Clear width of the modelled opening. Note
|
|
| OverallHeight ePset_OpeningDimensions · m |
Clear height of the modelled opening. Note
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| Width Qto_OpeningElementBaseQuantities · m |
Clear width of the modelled opening. |
|
| Height Qto_OpeningElementBaseQuantities · m |
Clear height of the modelled opening. |
|
| IsFireStoppingRequired ePset_FireStopping |
Marks whether the penetration has to be closed with a firestop. Allowed values
|
Related elements
-
STR-BEAM
Beam / girder detailed
Enables reliable coordination of load transfer, penetrations, and connections through to execution.
-
STR-COLUMN
Column detailed
Ensures coordinated load transfer and clash-free placement of adjacent components through to execution.
-
STR-FOOTING
Footing detailed
Provides a reliable basis for coordinating load transfer, excavation, and utility lines.