Planning constraint
ARC-CONSTRAINT
pragmaticBIM.ch/arc-constraint
Makes external requirements spatially verifiable from an early stage and supports quality assurance when checking the design against protection, hazard, and permitting requirements.
Description
- Volume representing a binding or governing external requirement (e.g. buildable envelope, flight corridor, flood zone, railway corridor).
- Used for early alignment of the design with base data and hazard/protection spaces - not for legal boundary determination.
Modelling guidelines
- Model as a simplified proxy body; footprint and height according to base data (cadastre, specialist authorities, reports).
- Assign to the planning perimeter or matching storey; ObjectType = Planning constraint.
- Name = kind of requirement from the value list.
- For Name = Buildable envelope, set the outer faces to the building limit, the alignment, and the step-backs.
- Do not model buildings, terrain, or finishes inside the volume.
IFC entity
- IFC4
- IfcBuildingElementProxy
- IFC4.3
- IfcBuildingElementProxy
- IFC2x3
- IfcBuildingElementProxy
- Applicability rule
- {'de': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType=Rahmenbedingung) OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType=Rahmenbedingung)', 'fr': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Condition-cadre") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Condition-cadre")', 'it': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Condizione quadro") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Condizione quadro")', 'en': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Planning constraint") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Planning constraint")'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Kind of planning-relevant constraint. Allowed values
|
|
| PredefinedType |
Marks the proxy as a user-defined type. Allowed values
|
|
| ObjectType |
Kind of proxy element. Allowed values
|
Related elements
-
ARC-MAINT-SPACE
Maintenance space
Ensures plant remains permanently accessible and can be maintained without spatial conflicts.
-
ARC-MOVEMENT-CLEARANCE
Movement clearance
Makes the areas that must remain clear for accessibility spatially verifiable so conflicts with building elements and furniture are found before the permit submission.
-
ARC-TURN-RAD
Turning radius
Demonstrates that vehicles can safely use the planned access routes and manoeuvring areas.