Element

Base slab

ARC-SLAB-BASE pragmaticBIM.ch/arc-slab-base

Makes the building support and load transfer into the ground spatially verifiable early and provides design certainty for basements, waterproofing, and excavation.

Base slab (ARC-SLAB-BASE)

Description

  • Coarsely dimensioned base or raft slab according to the structural concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model as a simplified volume; split at component boundaries.
  • Do not model reinforcement, foundation details, or layer build-ups.
  • During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcSlab
IFC4.3
IfcSlab
IFC2x3
IfcSlab
Applicability rule
entity_ifc4=IfcSlab AND PredefinedType=BASESLAB AND LoadBearing=TRUE

Attributes

PredefinedType

Marks the base slab.

Allowed values

  • BASESLAB - base slab
+9 more
LoadBearing Pset_SlabCommon

Marks the element as a load-bearing component in the architecture model.

Allowed values

  • TRUE - load-bearing component
+3 more
Status Pset_SlabCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+2 more
FireRating Pset_SlabCommon

Fire resistance class of the slab according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
AcousticRating Pset_SlabCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

ThermalTransmittance Pset_SlabCommon · W/(m²·K)

Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component.

+2 more
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+1 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
+1 more
eBKP ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • C01.03 - base slab
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic PlattenTypisierung (Prefix Bodenplatte). Example: Bodenplatte_Beton_300mm_0.17

+3 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+6 more
UnitPrice ePset_Cost · CHF/m³

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_SlabBaseQuantities.GrossVolume is the authoritative reference quantity for UnitPrice.

+3 more
Connection ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

HazardType ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

+1 more
SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

Width Qto_SlabBaseQuantities · m

Thickness of the modelled base slab.

+1 more
GrossVolume Qto_SlabBaseQuantities · m³

Gross volume of the modelled base slab.

+9 more
FireRatingRequired ePset_SlabRequirement

Required fire resistance of the component under the fire protection concept. Target value compared with FireRating.

ThermalTransmittanceMax ePset_SlabRequirement · W/(m²·K)

Maximum permitted thermal transmittance U [W/(m²·K)] of the component under the energy standard and the building physics concept. Target value compared with ThermalTransmittance.

GlobalWarmingPotentialMax ePset_SlabRequirement · kg CO₂-eq/m²

Maximum permitted greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area under the greenhouse gas target. Target value compared with GlobalWarmingPotential.

GlobalWarmingPotential ePset_Slab · kg CO₂-eq/m²

Greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area, calculated from the build-up and KBOB life-cycle data.

Related elements

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel