Flat roof
ARC-ROOF-FLAT
pragmaticBIM.ch/arc-roof-flat
Makes the structural concept and building enclosure spatially verifiable early and provides design certainty for levels, build-ups, and permitting.
Description
- Coarsely dimensioned flat roof slab according to the structural and envelope concept.
- Used for coordination between architecture and structural engineering, not for execution planning.
Modelling guidelines
- Model as a simplified volume; split at component boundaries.
- Do not model roof build-ups, drainage details, or layer build-ups.
- During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
- Use and export the appropriate material from the authoring system.
IFC entity
- IFC4
- IfcSlab
- IFC4.3
- IfcSlab
- IFC2x3
- IfcSlab
- Applicability rule
- entity_ifc4=IfcSlab AND PredefinedType=ROOF AND LoadBearing=TRUE
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Flat roof designation according to the structural plan. |
|
| PredefinedType |
Marks the flat roof. Allowed values
|
|
| IsExternal Pset_SlabCommon |
Marks the roof as an external element. Allowed values
|
+1 more |
| LoadBearing Pset_SlabCommon |
Marks the element as a load-bearing component in the architecture model. Allowed values
|
|
| Status Pset_SlabCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| FireRating Pset_SlabCommon |
Fire resistance class of the slab according to the fire protection concept. Allowed values
|
|
| AcousticRating Pset_SlabCommon |
Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w. |
|
| ThermalTransmittance Pset_SlabCommon · W/(m²·K) |
Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component. |
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
+1 more |
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
+1 more |
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain. Allowed values
|
|
| CalculatedType ePset_Cost |
Calculated type name for cost and quantity grouping. Logic |
|
| ProductClass ePset_Cost |
Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable. Allowed values
|
|
| UnitPrice ePset_Cost · CHF/m² |
Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility. |
|
| ReferenceQuantity ePset_Cost |
|
|
| Connection ePset_Circularity |
Connection type for detachability (Madaster). Allowed values
|
|
| Accessibility ePset_Circularity |
Accessibility of the connection without destroying the component or surroundings (Madaster). Allowed values
|
|
| Reuse ePset_Circularity |
Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %). |
|
| MaterialOrProductId ePset_Circularity |
Unique ID of the material or product in the linked database (e.g. Madaster, baubook). |
|
| WasteCodes ePset_Circularity |
Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. |
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
+1 more |
| HazardType ePset_HazardousMaterial |
Type of hazardous material found by survey on the affected existing component. Allowed values
|
|
| RemovalCategory ePset_HazardousMaterial |
Remediation urgency and action required, as determined by the survey. Allowed values
|
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| Width Qto_SlabBaseQuantities · m |
Thickness of the modelled flat roof. |
+1 more |
| GrossVolume Qto_SlabBaseQuantities · m³ |
Gross volume of the modelled flat roof. |
|
| GrossArea Qto_SlabBaseQuantities · m² |
Gross area of the modelled flat roof. |
|
| FireRatingRequired ePset_SlabRequirement |
Required fire resistance of the component under the fire protection concept. Target value compared with FireRating. |
|
| ThermalTransmittanceMax ePset_SlabRequirement · W/(m²·K) |
Maximum permitted thermal transmittance U [W/(m²·K)] of the component under the energy standard and the building physics concept. Target value compared with ThermalTransmittance. |
|
| GlobalWarmingPotentialMax ePset_SlabRequirement · kg CO₂-eq/m² |
Maximum permitted greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area under the greenhouse gas target. Target value compared with GlobalWarmingPotential. |
|
| GlobalWarmingPotential ePset_Slab · kg CO₂-eq/m² |
Greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area, calculated from the build-up and KBOB life-cycle data. |
|
| AirborneSoundInsulationMin ePset_SlabRequirement · dB |
Required airborne sound insulation De [dB] against exterior noise under SIA 181, depending on the exterior noise and the noise sensitivity of the rooms behind. Target value compared with AirborneSoundInsulation. |
+1 more |
| AirborneSoundInsulation ePset_Slab · dB |
Verified airborne sound insulation De [dB] of the installed component under the acoustic verification. |
+1 more |
Related elements
-
ARC-FOOTING
Footing
Makes the space and location required to transfer loads into the ground verifiable early and prevents conflicts with basements, services, and excavation.
-
ARC-WALL-INT
Non-load-bearing interior wall
Makes the spatial layout reliably verifiable early on and provides the basis for fire, acoustic, and interior-fit-out coordination.
-
ARC-WALL-INT-LB
Load-bearing interior wall
Makes load transfer and space separation jointly verifiable early on and provides a reliable basis for structural, fire, and acoustic coordination.