Element

Non-load-bearing interior wall

ARC-WALL-INT pragmaticBIM.ch/arc-wall-int

Makes the spatial layout reliably verifiable early on and provides the basis for fire, acoustic, and interior-fit-out coordination.

Non-load-bearing interior wall (ARC-WALL-INT)

Description

  • Non-load-bearing partition between interior spaces.
  • Used for coordination, fire and acoustic verification, and component identification.

Modelling guidelines

  • Model storey by storey; split at component and storey boundaries.
  • Set IsExternal=FALSE and LoadBearing=FALSE.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcWall
IFC4.3
IfcWall
IFC2x3
IfcWall
Applicability rule
(entity_ifc4=IfcWall AND IsExternal=FALSE AND LoadBearing=FALSE) OR (entity_ifc2x3=IfcWall AND IsExternal=FALSE AND LoadBearing=FALSE)

Attributes

PredefinedType

Kind of interior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
+12 more
Reference Pset_WallCommon

Interior wall reference according to the component catalogue.

+6 more
IsExternal Pset_WallCommon

Marks an interior wall.

Allowed values

  • FALSE - interior wall
+10 more
LoadBearing Pset_WallCommon

Marks the wall as non-load-bearing.

Allowed values

  • FALSE - non-load-bearing
+7 more
Status Pset_WallCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+4 more
FireRating Pset_WallCommon

Fire resistance class of the non-load-bearing interior wall according to the fire protection concept - integrity and insulation (EI) only, without load-bearing capacity.

Allowed values

  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
+4 more
AcousticRating Pset_WallCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

+4 more
ThermalTransmittance Pset_WallCommon · W/(m²·K)

Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component.

+3 more
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+4 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
+2 more
eBKP ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • G01.01 - fixed partition
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic WandTypisierung. Example: Wand_Innen_Oberirdisch_Beton_150mm_EI30_53

+5 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+8 more
UnitPrice ePset_Cost · CHF/m²

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_WallBaseQuantities.NetSideArea is the authoritative reference quantity for UnitPrice.

+3 more
Connection ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

+1 more
HazardType ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

NetSideArea Qto_WallBaseQuantities · m²

Net side area of the modelled interior wall.

+9 more
Width Qto_WallBaseQuantities · m

Thickness of the modelled interior wall.

+6 more
GrossVolume Qto_WallBaseQuantities · m³

Gross volume of the modelled interior wall.

FireRatingRequired ePset_WallRequirement

Required fire resistance of the component under the fire protection concept. Target value compared with FireRating.

+1 more
AirborneSoundInsulationMin ePset_WallRequirement · dB

Required airborne sound insulation Di [dB] between units under SIA 181. Target value compared with AirborneSoundInsulation.

+2 more
GlobalWarmingPotentialMax ePset_WallRequirement · kg CO₂-eq/m²

Maximum permitted greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area under the greenhouse gas target. Target value compared with GlobalWarmingPotential.

+1 more
AirborneSoundInsulation ePset_Wall · dB

Verified airborne sound insulation Di [dB] of the installed component under the acoustic verification.

+1 more
GlobalWarmingPotential ePset_Wall · kg CO₂-eq/m²

Greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area, calculated from the build-up and KBOB life-cycle data.

ReactionToFire ePset_ReactionToFire

Reaction-to-fire group (RF) of the component or its surface layer under the VKF fire protection regulations. Basis for checking VKF 14-15 on claddings, coverings and ceilings.

Allowed values

  • RF1 - no contribution to fire
  • RF2 - low contribution
  • RF3 - acceptable contribution
  • RF4 - unacceptable contribution

Note

  • The critical behaviour flag (cr) is not yet a value of this list.
ReactionToFireRequired ePset_WallRequirement

Required reaction-to-fire group (the worst group still permitted) of the component under VKF 14-15. Target value compared with ReactionToFire.

Allowed values

  • RF1 - no contribution to fire
  • RF2 - low contribution
  • RF3 - acceptable contribution
  • RF4 - unacceptable contribution

Note

  • RF1 is the best group: the requirement is met when the delivered group is equal or better. The cr flag is not yet a value of this list.