Element

Exterior window

ARC-WINDOW-EXT pragmaticBIM.ch/arc-window-ext

Ensures daylight, ventilation, and views and provides a verifiable basis for facade and building-physics design.

Exterior window (ARC-WINDOW-EXT)

Description

  • Exterior windows and skylights in the envelope.
  • Each window is assigned to a space.
  • Basis for facade planning, building physics (U-value), and tendering.

Modelling guidelines

  • Set IsExternal=TRUE.
  • Export glazing with a transparent material.
  • Relate each window to a space.

IFC entity

IFC4
IfcWindow
IFC4.3
IfcWindow
IFC2x3
IfcWindow
Applicability rule
(entity_ifc4=IfcWindow AND IsExternal=TRUE) OR (entity_ifc2x3=IfcWindow AND IsExternal=TRUE)

Attributes

Name

Window number according to the office standard.

+5 more
PredefinedType

Kind of window.

Allowed values

  • WINDOW - window
  • SKYLIGHT - skylight
  • LIGHTDOME - light dome
+15 more
OverallWidth m

Clear width of the window opening.

+7 more
OverallHeight m

Clear height of the window opening.

+7 more
IsExternal Pset_WindowCommon

Marks an exterior window.

Allowed values

  • TRUE - exterior window
+6 more
Status Pset_WindowCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+4 more
FireRating Pset_WindowCommon

Fire resistance class of the non-load-bearing window according to the fire protection concept - integrity and insulation (EI), without load-bearing capacity.

Allowed values

  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
+2 more
AcousticRating Pset_WindowCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

+2 more
SecurityRating Pset_WindowCommon

Burglary resistance class of the window according to the security concept and EN 1627.

Allowed values

  • RC1 - resistance class 1
  • RC2 - resistance class 2
  • RC3 - resistance class 3
  • RC4 - resistance class 4
  • RC5 - resistance class 5
  • RC6 - resistance class 6
ThermalTransmittance Pset_WindowCommon · W/(m²·K)

Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component.

+2 more
SunProtection ePset_SunProtection

Sun-protection type of the exterior window, even when the device is modelled as a separate component.

Allowed values

  • NONE - no sun protection
  • JALOUSIE - external slats / venetian blind
  • SHUTTER - shutter
  • AWNING - awning
  • USERDEFINED - other sun protection
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+4 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
eBKP ePset_Cost

eBKP-H classification according to SN 506 511.

Allowed values

  • E03.01 - exterior window
  • G01.04 - interior window
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic FensterTypisierung. Example: Fenster_Aussen_B=1.20m_H=1.40m_35_0.9_0.9

+3 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+6 more
UnitPrice ePset_Cost · CHF/m²

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_WindowBaseQuantities.Area is the authoritative reference quantity for UnitPrice.

+3 more
Connection ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

+1 more
HazardType ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

Area Qto_WindowBaseQuantities · m²

Area of the window opening.

+7 more
DaylightSpaceReference ePset_Daylight

Technical room number of the interior space the window is geometrically assigned to for the daylight verification.

GlazingArea ePset_Daylight · m²

Projected net area of the transparent glazing, excluding frame and opaque infills.

AirborneSoundInsulationMin ePset_WindowRequirement · dB

Required airborne sound insulation De [dB] against exterior noise under SIA 181, depending on the exterior noise and the noise sensitivity of the rooms behind. Target value compared with AirborneSoundInsulation.

+1 more
AirborneSoundInsulation ePset_Window · dB

Verified airborne sound insulation De [dB] of the installed component under the acoustic verification.

+1 more