Exterior window
ARC-WINDOW-EXT
pragmaticBIM.ch/arc-window-ext
Ensures daylight, ventilation, and views and provides a verifiable basis for facade and building-physics design.
Description
- Exterior windows and skylights in the envelope.
- Each window is assigned to a space.
- Basis for facade planning, building physics (U-value), and tendering.
Modelling guidelines
- Set IsExternal=TRUE.
- Export glazing with a transparent material.
- Relate each window to a space.
IFC entity
- IFC4
- IfcWindow
- IFC4.3
- IfcWindow
- IFC2x3
- IfcWindow
- Applicability rule
- (entity_ifc4=IfcWindow AND IsExternal=TRUE) OR (entity_ifc2x3=IfcWindow AND IsExternal=TRUE)
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Window number according to the office standard. |
|
| PredefinedType |
Kind of window. Allowed values
|
|
| OverallWidth m |
Clear width of the window opening. |
|
| OverallHeight m |
Clear height of the window opening. |
|
| IsExternal Pset_WindowCommon |
Marks an exterior window. Allowed values
|
|
| Status Pset_WindowCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| FireRating Pset_WindowCommon |
Fire resistance class of the non-load-bearing window according to the fire protection concept - integrity and insulation (EI), without load-bearing capacity. Allowed values
|
|
| AcousticRating Pset_WindowCommon |
Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w. |
|
| SecurityRating Pset_WindowCommon |
Burglary resistance class of the window according to the security concept and EN 1627. Allowed values
|
|
| ThermalTransmittance Pset_WindowCommon · W/(m²·K) |
Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component. |
|
| SunProtection ePset_SunProtection |
Sun-protection type of the exterior window, even when the device is modelled as a separate component. Allowed values
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
+1 more |
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511. Allowed values
|
|
| CalculatedType ePset_Cost |
Calculated type name for cost and quantity grouping. Logic |
|
| ProductClass ePset_Cost |
Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable. Allowed values
|
|
| UnitPrice ePset_Cost · CHF/m² |
Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility. |
|
| ReferenceQuantity ePset_Cost |
|
|
| Connection ePset_Circularity |
Connection type for detachability (Madaster). Allowed values
|
|
| Accessibility ePset_Circularity |
Accessibility of the connection without destroying the component or surroundings (Madaster). Allowed values
|
|
| Reuse ePset_Circularity |
Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %). |
|
| MaterialOrProductId ePset_Circularity |
Unique ID of the material or product in the linked database (e.g. Madaster, baubook). |
|
| WasteCodes ePset_Circularity |
Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. |
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
+1 more |
| HazardType ePset_HazardousMaterial |
Type of hazardous material found by survey on the affected existing component. Allowed values
|
|
| RemovalCategory ePset_HazardousMaterial |
Remediation urgency and action required, as determined by the survey. Allowed values
|
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| Area Qto_WindowBaseQuantities · m² |
Area of the window opening. |
|
| DaylightSpaceReference ePset_Daylight |
Technical room number of the interior space the window is geometrically assigned to for the daylight verification. |
|
| GlazingArea ePset_Daylight · m² |
Projected net area of the transparent glazing, excluding frame and opaque infills. |
|
| AirborneSoundInsulationMin ePset_WindowRequirement · dB |
Required airborne sound insulation De [dB] against exterior noise under SIA 181, depending on the exterior noise and the noise sensitivity of the rooms behind. Target value compared with AirborneSoundInsulation. |
+1 more |
| AirborneSoundInsulation ePset_Window · dB |
Verified airborne sound insulation De [dB] of the installed component under the acoustic verification. |
+1 more |
Related elements
-
ARC-DOOR-EXT
Exterior door
Ensures functional building access and provides the basis for escape-route, facade, and building-physics design.
-
ARC-OPENING-VOID
Opening / recess (architecture)
Secures the required routes for services and installations and prevents uncoordinated penetrations between architecture, structure, and building services.
-
ARC-WINDOW-INT
Interior window
Ensures daylight transfer between interior spaces and provides a verifiable basis for spatial and acoustic design.