Suspended ceiling
ARC-CEILING
pragmaticBIM.ch/arc-ceiling
Ensures coordinated room heights, ceiling design, and building services.
Description
- Interior and exterior suspended ceilings with a defined underside.
- Includes access openings and reservations for building services.
Modelling guidelines
- In early phases, model only in exceptional cases; record the attribute on the space instead (
FinishCeilingHeight). - Model as one layer with final surface.
- Model thickness including the substructure - not only the gypsum board (e.g. not 2 cm, but about 7 cm with substructure).
- Model access openings as IfcDoor with PredefinedType=TRAPDOOR in the ceiling.
- Use and export the appropriate material from the authoring system.
IFC entity
- IFC4
- IfcCovering
- IFC4.3
- IfcCovering
- IFC2x3
- IfcCovering
- Applicability rule
- entity_ifc4=IfcCovering AND PredefinedType=CEILING
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Marks the suspended ceiling. Allowed values
|
|
| IsExternal Pset_CoveringCommon |
Indicates whether the suspended ceiling is interior or exterior. Allowed values
|
+1 more |
| Status Pset_CoveringCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
+1 more |
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain. Allowed values
|
|
| ProductClass ePset_Cost |
Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable. Allowed values
|
|
| UnitPrice ePset_Cost · CHF/m² |
Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility. |
|
| ReferenceQuantity ePset_Cost |
|
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| NetArea Qto_CoveringBaseQuantities · m² |
Net area of the modelled suspended ceiling. |
|
| ReactionToFire ePset_ReactionToFire |
Reaction-to-fire group (RF) of the component or its surface layer under the VKF fire protection regulations. Basis for checking VKF 14-15 on claddings, coverings and ceilings. Allowed values
Note
|
|
| ReactionToFireRequired ePset_CoveringRequirement |
Required reaction-to-fire group (the worst group still permitted) of the component under VKF 14-15. Target value compared with ReactionToFire. Allowed values
Note
|
Related elements
-
ARC-FLOOR-COV
Interior floor build-up
Provides a reliable basis for level coordination, joint design, tendering, and quantity take-off for interior finishes. Modelled in every room from tendering on; before that and in operation, the floor finish sits on the interior space.
-
ARC-FLOOR-COV-EXT
Exterior floor covering
Makes exterior finishes verifiable in detail design for quantities, joints, and tendering. Early planning without a modelled covering: FloorCovering (AOF) on the exterior space.
-
ARC-WALL-CLAD-EXT
Facade cladding
Enables separate design and quantity take-off of the facade surface and improves coordination with connections and openings.