Element

Suspended ceiling

ARC-CEILING pragmaticBIM.ch/arc-ceiling

Ensures coordinated room heights, ceiling design, and building services.

Suspended ceiling (ARC-CEILING)

Description

  • Interior and exterior suspended ceilings with a defined underside.
  • Includes access openings and reservations for building services.

Modelling guidelines

  • In early phases, model only in exceptional cases; record the attribute on the space instead (FinishCeilingHeight).
  • Model as one layer with final surface.
  • Model thickness including the substructure - not only the gypsum board (e.g. not 2 cm, but about 7 cm with substructure).
  • Model access openings as IfcDoor with PredefinedType=TRAPDOOR in the ceiling.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcCovering
IFC4.3
IfcCovering
IFC2x3
IfcCovering
Applicability rule
entity_ifc4=IfcCovering AND PredefinedType=CEILING

Attributes

PredefinedType

Marks the suspended ceiling.

Allowed values

  • CEILING - suspended ceiling
+5 more
IsExternal Pset_CoveringCommon

Indicates whether the suspended ceiling is interior or exterior.

Allowed values

  • TRUE - exterior suspended ceiling
  • FALSE - interior suspended ceiling
+1 more
Status Pset_CoveringCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+2 more
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+2 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
eBKP ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • G04.02 - ceiling covering
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+6 more
UnitPrice ePset_Cost · CHF/m²

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_CoveringBaseQuantities.NetArea is the authoritative reference quantity for UnitPrice.

+3 more
GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

NetArea Qto_CoveringBaseQuantities · m²

Net area of the modelled suspended ceiling.

+8 more
ReactionToFire ePset_ReactionToFire

Reaction-to-fire group (RF) of the component or its surface layer under the VKF fire protection regulations. Basis for checking VKF 14-15 on claddings, coverings and ceilings.

Allowed values

  • RF1 - no contribution to fire
  • RF2 - low contribution
  • RF3 - acceptable contribution
  • RF4 - unacceptable contribution

Note

  • The critical behaviour flag (cr) is not yet a value of this list.
ReactionToFireRequired ePset_CoveringRequirement

Required reaction-to-fire group (the worst group still permitted) of the component under VKF 14-15. Target value compared with ReactionToFire.

Allowed values

  • RF1 - no contribution to fire
  • RF2 - low contribution
  • RF3 - acceptable contribution
  • RF4 - unacceptable contribution

Note

  • RF1 is the best group: the requirement is met when the delivered group is equal or better. The cr flag is not yet a value of this list.

Related elements