Air spaces
SPACE-AIR
pragmaticBIM.ch/space-air
Prevents non-occupiable volumes from being counted as floor area while providing a spatial reference for building services.
Description
- Air spaces such as atriums, stair voids, multi-storey rooms, or other non-occupiable volumes within the storey volume.
- Deducted from storey volume to obtain countable floor area or usable volume.
- Provide a reference space for building services engineers.
Modelling guidelines
- Fill every larger cavity in the building with an air space - e.g. atrium, stair void, multi-storey rooms, air space above the uppermost stair flight.
- Model as a volume with the space tool, storey by storey.
- Bottom = top of the space volume below; top = underside of the raw slab or boundary of the storey volume.
- Assign to the matching storey; no overlaps with usable spaces or duplicates.
Discussion point
- Air spaces are still rarely modelled as separate volumes. Instead, teams often create a storey volume for urban-design evaluations and building volume together with a storey-area model. A separate air space can be evaluated directly, reused for subsequent area and volume calculations, and made available to building services as a spatial reference. It also represents a real spatial condition that is intuitively understandable, whereas interpreting a storey-area model requires knowledge of the underlying standard.
IFC entity
- IFC4
- IfcSpace
- IFC4.3
- IfcSpace
- IFC2x3
- IfcSpace
- Applicability rule
- {'de': '(entity_ifc4=IfcSpace AND PredefinedType=USERDEFINED AND ObjectType=Luftraum) OR (entity_ifc2x3=IfcSpace AND ObjectType=Luftraum)', 'fr': '(entity_ifc4=IfcSpace AND PredefinedType=USERDEFINED AND ObjectType="Volume d\'air") OR (entity_ifc2x3=IfcSpace AND ObjectType="Volume d\'air")', 'it': '(entity_ifc4=IfcSpace AND PredefinedType=USERDEFINED AND ObjectType="Volume d\'aria") OR (entity_ifc2x3=IfcSpace AND ObjectType="Volume d\'aria")', 'en': '(entity_ifc4=IfcSpace AND PredefinedType=USERDEFINED AND ObjectType="Air space") OR (entity_ifc2x3=IfcSpace AND ObjectType="Air space")'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Optional designation or number of the air space according to the project. |
|
| PredefinedType |
Marks the space as a user-defined type; ObjectType specifies the kind. Allowed values
|
|
| ObjectType |
Kind of user-defined space. Allowed values
|
|
| GrossFloorArea Qto_SpaceBaseQuantities · m² |
Footprint area of the modelled air space. |
|
| GrossVolume Qto_SpaceBaseQuantities · m³ |
Volume of the modelled air space. |
+1 more |
| Height Qto_SpaceBaseQuantities · m |
Height of the modelled air space. |
Related elements
-
SPACE-PARK
Parking spaces
Enables traceable parking verification and reliable area and traffic planning from the building design phase onward.
-
SPACE-VORSATZ
Wall lining (usable space)
Makes space and floor-area loss verifiable early so that rooms, especially sanitary spaces, can be sized adequately.
-
ARC-WALL-EXT
Exterior wall
Exterior walls provide the basis for area and quantity take-off, building physics, and facade coordination.