Light fixture
MEP-LIGHT
pragmaticBIM.ch/mep-light
Enables lighting verification and coordination of ceiling layout, power supply, and maintenance access.
Description
- Luminaire for lighting rooms or areas.
- Light fixture.
Modelling guidelines
- Model as an equipment object with size and location.
- Assign to the matching storey and technical or use zone.
IFC entity
- IFC4
- IfcLightFixture
- IFC4.3
- IfcLightFixture
- IFC2x3
- IfcFlowTerminal
- Applicability rule
- entity_ifc4=IfcLightFixture
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Kind of equipment or terminal. Allowed values
|
+1 more |
| Tag |
Plant identification (AKS) to the client standard. Where no project-specific standard applies, we suggest |
|
| Status Pset_LightFixtureTypeCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| WarrantyEndDate Pset_Warranty |
Warranty end date - to be provided by the contractor. |
|
| DatasheetLink ePset_ProductData |
Link (URI) to the product datasheet. |
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
|
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from element type, medium, and BelowTerrain. Allowed values
|
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| SafetyRatedDuration ePset_SafetyLighting · min |
Rated operating time of the safety luminaire when the normal lighting fails [min] (VKF 17-15, Ziff. 3.2.1). |
|
| SafetyStartUpTime ePset_SafetyLighting · s |
Time until the safety luminaire operates after a failure of the general power supply [s] (VKF 17-15, Ziff. 3.2.2). |
|
| SafetySupplyType ePset_SafetyLighting |
Safety power source of the safety luminaire (VKF 17-15, Ziff. 3.2.2, 3.3). Allowed values
|
|
| SafetyFloorIlluminance ePset_SafetyLighting · lx |
Planned illuminance of the safety lighting at floor level of the escape route [lx] (VKF 17-15, Ziff. 3.2.4). |
|
| SafetyNotSwitchable ePset_SafetyLighting |
Marks whether the safety luminaire cannot be switched off by a main switch or by the room lighting switch (VKF 17-15, Ziff. 3.2.2). Allowed values
|
Related elements
-
MEP-OUTLET
Socket / data outlet
Fixes connection points so use, service routes, and finishes can be coordinated.
-
MEP-SWITCH
Switch
Fixes control and switching points so electrical function, finishes, and user access can be coordinated.
-
MEP-DAMPER
Damper
Fixes air isolation and control points so airflow, fire safety, and maintenance access can be coordinated.