Exterior door
ARC-DOOR-EXT
pragmaticBIM.ch/arc-door-ext
Ensures functional building access and provides the basis for escape-route, facade, and building-physics design.
Description
- Exterior doors, gates, and inspection openings to the outside.
- Basis for facade planning, building physics (U-value), and tendering.
Modelling guidelines
- Set IsExternal=TRUE.
- Glazed areas with a transparent material.
- Use and export the appropriate material from the authoring system.
IFC entity
- IFC4
- IfcDoor
- IFC4.3
- IfcDoor
- IFC2x3
- IfcDoor
- Applicability rule
- (entity_ifc4=IfcDoor AND IsExternal=TRUE) OR (entity_ifc2x3=IfcDoor AND IsExternal=TRUE)
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Door number according to office standard. Recommendation: T{room number of the space the door opens into}. This requires outdoor spaces to receive a room number as well. |
|
| PredefinedType |
Kind of door. Allowed values
|
|
| OverallWidth m |
Clear width of the door opening. |
|
| OverallHeight m |
Clear height of the door opening. |
|
| OperationType |
Door opening type and direction. Allowed values
|
|
| Reference Pset_DoorCommon |
Door reference used for coordination. |
|
| IsExternal Pset_DoorCommon |
Marks an exterior door. Allowed values
|
|
| Status Pset_DoorCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| FireRating Pset_DoorCommon |
Fire resistance class of the non-load-bearing door according to the fire protection concept - integrity and insulation (EI), without load-bearing capacity. Allowed values
|
|
| AcousticRating Pset_DoorCommon |
Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w. |
|
| SecurityRating Pset_DoorCommon |
Burglary resistance class of the door according to the security concept and EN 1627. Allowed values
|
|
| ThermalTransmittance Pset_DoorCommon · W/(m²·K) |
Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component. |
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
+1 more |
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511. Allowed values
|
|
| CalculatedType ePset_Cost |
Calculated type name for cost and quantity grouping. Logic |
|
| ProductClass ePset_Cost |
Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable. Allowed values
|
|
| UnitPrice ePset_Cost · CHF/m² |
Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility. |
|
| ReferenceQuantity ePset_Cost |
|
|
| Connection ePset_Circularity |
Connection type for detachability (Madaster). Allowed values
|
|
| Accessibility ePset_Circularity |
Accessibility of the connection without destroying the component or surroundings (Madaster). Allowed values
|
|
| Reuse ePset_Circularity |
Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %). |
|
| MaterialOrProductId ePset_Circularity |
Unique ID of the material or product in the linked database (e.g. Madaster, baubook). |
|
| WasteCodes ePset_Circularity |
Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. |
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
+1 more |
| HazardType ePset_HazardousMaterial |
Type of hazardous material found by survey on the affected existing component. Allowed values
|
|
| RemovalCategory ePset_HazardousMaterial |
Remediation urgency and action required, as determined by the survey. Allowed values
|
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| Area Qto_DoorBaseQuantities · m² |
Area of the door opening. |
|
| AirborneSoundInsulationMin ePset_DoorRequirement · dB |
Required airborne sound insulation De [dB] against exterior noise under SIA 181, depending on the exterior noise and the noise sensitivity of the rooms behind. Target value compared with AirborneSoundInsulation. |
+1 more |
| AirborneSoundInsulation ePset_Door · dB |
Verified airborne sound insulation [dB] of the installed door under the acoustic verification. |
+1 more |
Related elements
-
ARC-OPENING-VOID
Opening / recess (architecture)
Secures the required routes for services and installations and prevents uncoordinated penetrations between architecture, structure, and building services.
-
ARC-WINDOW-INT
Interior window
Ensures daylight transfer between interior spaces and provides a verifiable basis for spatial and acoustic design.
-
ARC-DOOR-INT
Interior door / inspection hatch
Ensures functional connections between spaces and provides the basis for escape-route, fire, and acoustic design.