Firestop / acoustic seal
ARC-FIRE-ACOUSTIC-SEAL
pragmaticBIM.ch/arc-fire-acoustic-seal
Separates the installed seal from the opening and makes its type, performance, and quantity verifiable for tendering, construction, and operation.
Description
- Construction seal around a service penetration that resists the spread of fire, smoke, or sound.
- Standalone component within a coordinated opening; the opening remains a separate opening element.
Modelling guidelines
- Model as a simplified proxy body within the associated opening; its dimensions represent the sealed area.
- Identify it unambiguously with its own Reference and assign it to exactly one opening through OpeningReference.
- Set ObjectType = Firestop or Acoustic seal; carry combined requirements in one element and state both performance ratings.
IFC entity
- IFC4
- IfcBuildingElementProxy
- IFC4.3
- IfcBuildingElementProxy
- IFC2x3
- IfcBuildingElementProxy
- Applicability rule
- {'de': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND (ObjectType=Brandschott OR ObjectType=Schallschutzschott)) OR (entity_ifc2x3=IfcBuildingElementProxy AND (ObjectType=Brandschott OR ObjectType=Schallschutzschott))', 'fr': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND (ObjectType="Obturation coupe-feu" OR ObjectType="Obturation acoustique")) OR (entity_ifc2x3=IfcBuildingElementProxy AND (ObjectType="Obturation coupe-feu" OR ObjectType="Obturation acoustique"))', 'it': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND (ObjectType="Sigillatura tagliafuoco" OR ObjectType="Sigillatura acustica")) OR (entity_ifc2x3=IfcBuildingElementProxy AND (ObjectType="Sigillatura tagliafuoco" OR ObjectType="Sigillatura acustica"))', 'en': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND (ObjectType=Firestop OR ObjectType="Acoustic seal")) OR (entity_ifc2x3=IfcBuildingElementProxy AND (ObjectType=Firestop OR ObjectType="Acoustic seal"))'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Seal designation for assignment in the model, schedule, and on site. |
|
| PredefinedType |
Marks the proxy as a user-defined type. Allowed values
|
+1 more |
| ObjectType |
Kind of seal. Allowed values
|
+1 more |
| Reference Pset_BuildingElementProxyCommon |
Unambiguous seal reference for tendering, acceptance, and operation. |
|
| OpeningReference ePset_Seal |
Reference of the opening containing the seal. |
|
| FireRating ePset_FireStopping |
Fire resistance class of the firestop under the fire protection concept. Allowed values
|
+1 more |
| AcousticRating ePset_Seal |
Weighted sound reduction index Rw [dB] of the acoustic seal. |
|
| FireStoppingType ePset_FireStopping |
Firestop type foreseen as the basis for tendering, installation, and maintenance. |
|
| Area Qto_BuildingElementProxyBaseQuantities · m² |
Area of the modelled seal. |
Related elements
-
ARC-CEILING
Suspended ceiling
Ensures coordinated room heights, ceiling design, and building services.
-
ARC-FLOOR-COV
Interior floor build-up
Provides a reliable basis for level coordination, joint design, tendering, and quantity take-off for interior finishes. Modelled in every room from tendering on; before that and in operation, the floor finish sits on the interior space.
-
ARC-FLOOR-COV-EXT
Exterior floor covering
Makes exterior finishes verifiable in detail design for quantities, joints, and tendering. Early planning without a modelled covering: FloorCovering (AOF) on the exterior space.