Interior wall cladding
ARC-WALL-CLAD
pragmaticBIM.ch/arc-wall-clad
Enables room-specific design and quantity take-off of surface finishes for tendering and interior-fit-out coordination.
Description
- Wall surface with defined quality according to the component catalogue.
- Separate layer, distinct from the load-bearing wall.
Modelling guidelines
- Model as a separate layer; split at room and component boundaries.
- Capture surface quality via Reference.
- Do not model execution details such as connection profiles.
- Use and export the appropriate material from the authoring system.
IFC entity
- IFC4
- IfcCovering
- IFC4.3
- IfcCovering
- IFC2x3
- IfcCovering
- Applicability rule
- entity_ifc4=IfcCovering AND PredefinedType=CLADDING AND IsExternal=FALSE
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Marks the interior wall cladding. Allowed values
|
|
| Reference Pset_CoveringCommon |
Surface quality of the interior wall cladding according to the component catalogue. Allowed values
|
+1 more |
| IsExternal Pset_CoveringCommon |
Marks the interior wall cladding. Allowed values
|
|
| Status Pset_CoveringCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
+1 more |
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
+1 more |
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain. Allowed values
|
|
| ProductClass ePset_Cost |
Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable. Allowed values
|
|
| UnitPrice ePset_Cost · CHF/m² |
Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility. |
|
| ReferenceQuantity ePset_Cost |
|
|
| Connection ePset_Circularity |
Connection type for detachability (Madaster). Allowed values
|
|
| Accessibility ePset_Circularity |
Accessibility of the connection without destroying the component or surroundings (Madaster). Allowed values
|
|
| Reuse ePset_Circularity |
Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %). |
|
| MaterialOrProductId ePset_Circularity |
Unique ID of the material or product in the linked database (e.g. Madaster, baubook). |
|
| WasteCodes ePset_Circularity |
Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. |
|
| HazardType ePset_HazardousMaterial |
Type of hazardous material found by survey on the affected existing component. Allowed values
|
|
| RemovalCategory ePset_HazardousMaterial |
Remediation urgency and action required, as determined by the survey. Allowed values
|
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
+1 more |
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
|
| NetArea Qto_CoveringBaseQuantities · m² |
Net area of the modelled interior wall cladding. |
|
| ReactionToFire ePset_ReactionToFire |
Reaction-to-fire group (RF) of the component or its surface layer under the VKF fire protection regulations. Basis for checking VKF 14-15 on claddings, coverings and ceilings. Allowed values
Note
|
|
| ReactionToFireRequired ePset_CoveringRequirement |
Required reaction-to-fire group (the worst group still permitted) of the component under VKF 14-15. Target value compared with ReactionToFire. Allowed values
Note
|
Related elements
-
ARC-DRYWALL-REINF
Drywall reinforcement zone
Makes required fixing support spatially checkable before tendering and construction and prevents subsequent daywork.
-
LAN-TREE
Tree
Makes decisions on protection, removal, and new planting spatially verifiable so that the building and external works account for the tree inventory.
-
SURVEY-SURFACE
Surface geometry
Provides existing and designed terrain so that connections to the building and earth quantities can be planned in coordination.