Lift
SPACE-ELEVATOR
pragmaticBIM.ch/space-elevator
Enables the occupied area to be assigned by storey so that area verification can be maintained correctly.
Description
- The elevator space object describes the space occupied by the elevator on each storey, not the physical lifting equipment.
- Storey-by-storey separation enables correct area classification, e.g. according to SIA 416 or DIN 277.
Modelling guidelines
- Model a separate volume with the space tool on each storey; do not create a space object spanning several storeys.
- Assign a unique Name on each storey, set LongName = Elevator, and record the area class in Reference (e.g.
VForVF-9).
IFC entity
- IFC4
- IfcSpace
- IFC4.3
- IfcSpace
- IFC2x3
- IfcSpace
- Applicability rule
- {'de': '(entity_ifc4=IfcSpace AND PredefinedType=SPACE AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Aufzug) OR (entity_ifc2x3=IfcSpace AND InteriorOrExteriorSpace=INTERNAL AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Aufzug)', 'fr': '(entity_ifc4=IfcSpace AND PredefinedType=SPACE AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Ascenseur) OR (entity_ifc2x3=IfcSpace AND InteriorOrExteriorSpace=INTERNAL AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Ascenseur)', 'it': '(entity_ifc4=IfcSpace AND PredefinedType=SPACE AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Ascensore) OR (entity_ifc2x3=IfcSpace AND InteriorOrExteriorSpace=INTERNAL AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Ascensore)', 'en': '(entity_ifc4=IfcSpace AND PredefinedType=SPACE AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Elevator) OR (entity_ifc2x3=IfcSpace AND InteriorOrExteriorSpace=INTERNAL AND Pset_SpaceCommon.IsExternal=FALSE AND LongName=Elevator)'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Unique technical designation of the elevator space object on each storey. |
|
| LongName |
Fixed use of the space object. Allowed values
|
|
| PredefinedType |
Marks the object as a space. Allowed values
Note
|
|
| InteriorOrExteriorSpace |
Marks the elevator space object as an interior space. Allowed values
Note
|
|
| Reference Pset_SpaceCommon |
Area class of the elevator space object according to SIA 416 or SIA D0165. Allowed values
|
+2 more |
| IsExternal Pset_SpaceCommon |
Marks the elevator space object as an interior space. Allowed values
|
|
| NetFloorArea Qto_SpaceBaseQuantities · m² |
Net floor area of the modelled elevator space object. |
+3 more |
| GrossVolume Qto_SpaceBaseQuantities · m³ |
Gross volume of the modelled elevator space object. |
+1 more |
Related elements
-
SPACE-AIR
Air spaces
Prevents non-occupiable volumes from being counted as floor area while providing a spatial reference for building services.
-
SPACE-PARK
Parking spaces
Enables traceable parking verification and reliable area and traffic planning from the building design phase onward.
-
SPACE-VORSATZ
Wall lining (usable space)
Makes space and floor-area loss verifiable early so that rooms, especially sanitary spaces, can be sized adequately.