Sanitary terminal
MEP-SANITARY
pragmaticBIM.ch/mep-sanitary
Fixes sanitary fixtures so use, water connections, drainage, and space requirements can be coordinated.
Description
- Sanitary fixture on the potable water and drainage network.
- Shower; tap; WC flush.
Modelling guidelines
- Model as an equipment object with size and location.
- Assign to the matching storey and technical or use zone.
IFC entity
- IFC4
- IfcSanitaryTerminal
- IFC4.3
- IfcSanitaryTerminal
- IFC2x3
- IfcFlowTerminal
- Applicability rule
- entity_ifc4=IfcSanitaryTerminal
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| PredefinedType |
Kind of equipment or terminal. Allowed values
|
+1 more |
| Tag |
Plant identification (AKS) to the client standard. Where no project-specific standard applies, we suggest |
|
| Status Pset_SanitaryTerminalTypeCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| WarrantyEndDate Pset_Warranty |
Warranty end date - to be provided by the contractor. |
|
| DatasheetLink ePset_ProductData |
Link (URI) to the product datasheet. |
|
| CostInterface ePset_Cost |
Cost interface: base building or tenant fit-out. Allowed values
|
|
| FundingApplication ePset_Cost |
Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. |
|
| AwardInterface ePset_Cost |
Procurement package of the component, so interfaces between contractor packages become visible. Allowed values
|
|
| PlanningInterface ePset_Cost |
Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible. Allowed values
|
|
| BelowTerrain ePset_Cost |
Marks whether the component sits below ground level. Allowed values
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511 - derivable from element type, medium, and BelowTerrain. Allowed values
|
|
| GlobalTradeItemNumber Pset_ManufacturerTypeInformation |
GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure. |
|
| SerialNumber Pset_ManufacturerOccurrence |
Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item. |
Related elements
-
MEP-WASTE
Waste terminal
Fixes drainage points so falls, pipe routes, and sanitary fixtures can be coordinated.
-
MEP-GAS-TERM
Gas outlet
Fixes gas draw-off points so pipe routes, isolation, and appliance connections can be coordinated.
-
MEP-FIRE-TERM
Fire suppression terminal
Enables verification of fire-suppression coverage and coordination of the required clearances.