Element

Interior door / inspection hatch

ARC-DOOR-INT pragmaticBIM.ch/arc-door-int

Ensures functional connections between spaces and provides the basis for escape-route, fire, and acoustic design.

Interior door / inspection hatch (ARC-DOOR-INT)

Description

  • Interior doors, gates, and inspection openings between rooms.
  • Basis for fire protection, acoustics, and door planning.

Modelling guidelines

  • Set IsExternal=FALSE.
  • Glazed areas with a transparent material.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcDoor
IFC4.3
IfcDoor
IFC2x3
IfcDoor
Applicability rule
(entity_ifc4=IfcDoor AND IsExternal=FALSE) OR (entity_ifc2x3=IfcDoor AND IsExternal=FALSE)

Attributes

Name

Door number according to office standard. Recommendation: T{room number of the space the door opens into}. This requires outdoor spaces to receive a room number as well.

+7 more
PredefinedType

Kind of door.

Allowed values

  • DOOR - door
  • GATE - gate
  • TRAPDOOR - trapdoor
+18 more
OverallWidth m

Clear width of the door opening.

+9 more
OverallHeight m

Clear height of the door opening.

+8 more
OperationType

Door opening type and direction.

Allowed values

  • SINGLE_SWING_LEFT - single swing, hinge left
  • SINGLE_SWING_RIGHT - single swing, hinge right
  • DOUBLE_DOOR_SINGLE_SWING - double door, same swing
  • DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_LEFT - double door, opposite swing, left
  • DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_RIGHT - double door, opposite swing, right
  • DOUBLE_SWING_LEFT - double swing, left
  • DOUBLE_SWING_RIGHT - double swing, right
  • DOUBLE_DOOR_DOUBLE_SWING - double door, double swing
  • SLIDING_TO_LEFT - sliding to left
  • SLIDING_TO_RIGHT - sliding to right
  • DOUBLE_DOOR_SLIDING - double sliding door
  • FOLDING_TO_LEFT - folding to left
  • FOLDING_TO_RIGHT - folding to right
  • DOUBLE_DOOR_FOLDING - double folding door
  • REVOLVING - revolving
  • ROLLINGUP - rolling shutter
  • SWING_FIXED_LEFT - swing fixed left
  • SWING_FIXED_RIGHT - swing fixed right
  • USERDEFINED - user-defined
  • NOTDEFINED - not defined
+2 more
Reference Pset_DoorCommon

Door reference used for coordination.

IsExternal Pset_DoorCommon

Marks an interior door.

Allowed values

  • FALSE - interior door
+5 more
Status Pset_DoorCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+5 more
FireRating Pset_DoorCommon

Fire resistance class of the non-load-bearing door according to the fire protection concept - integrity and insulation (EI), without load-bearing capacity.

Allowed values

  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
+2 more
AcousticRating Pset_DoorCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

+2 more
SecurityRating Pset_DoorCommon

Burglary resistance class of the door according to the security concept and EN 1627.

Allowed values

  • RC1 - resistance class 1
  • RC2 - resistance class 2
  • RC3 - resistance class 3
  • RC4 - resistance class 4
  • RC5 - resistance class 5
  • RC6 - resistance class 6
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+5 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
eBKP ePset_Cost

eBKP-H classification according to SN 506 511.

Allowed values

  • E03.02 - exterior door
  • G01.05 - interior door
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic TuerTypisierung. Example: Tür_Innen_1F_B=0.90m_H=2.10m_EI30

+3 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+6 more
UnitPrice ePset_Cost · CHF/m²

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_DoorBaseQuantities.Area is the authoritative reference quantity for UnitPrice.

+3 more
Connection ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

+1 more
HazardType ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

Area Qto_DoorBaseQuantities · m²

Area of the door opening.

+10 more
AirborneSoundInsulationMin ePset_DoorRequirement · dB

Required airborne sound insulation [dB] of the door between different usage units under SIA 181, such as the apartment entrance door to the stairwell. Target value compared with AirborneSoundInsulation.

+1 more
AirborneSoundInsulation ePset_Door · dB

Verified airborne sound insulation [dB] of the installed door under the acoustic verification.

+1 more

Related elements