Shading device
ARC-SHADING
pragmaticBIM.ch/arc-shading
Makes external sun protection visible in the model so location, type, and shading are recorded for facade planning and thermal simulation.
Description
- External devices such as slats, external blinds, awnings, or shutters in front of or above windows.
- Supports spatial coordination on the facade and provides additional context for heating-demand verification; it is not intended for shop drawings.
Modelling guidelines
- Model as a simplified external volume (slats, external blind, awning, shutters).
- Do not model motors, guide rails, or fabric folds.
- Place storey-wise and assign to the facade or the host window.
IFC entity
- IFC4
- IfcShadingDevice
- IFC4.3
- IfcShadingDevice
- IFC2x3
- IfcBuildingElementProxy
- Applicability rule
- {'de': 'entity_ifc4=IfcShadingDevice OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType=Sonnenschutz)', 'fr': 'entity_ifc4=IfcShadingDevice OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Protection solaire")', 'it': 'entity_ifc4=IfcShadingDevice OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Protezione solare")', 'en': 'entity_ifc4=IfcShadingDevice OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Shading device")'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Shading-device designation according to the facade or architecture drawing. |
|
| PredefinedType |
Type of sun protection. Allowed values
|
|
| ObjectType |
Kind of element as a shading device. Allowed values
Note
|
|
| IsExternal Pset_ShadingDeviceCommon |
Marks external sun protection. Allowed values
|
|
| Status Pset_ShadingDeviceCommon |
Component status for coordinating work in existing buildings. Allowed values
|
|
| ElementStatus ePset_ElementStatus |
Component status for coordinating work in existing buildings. Allowed values
Note
|
|
| eBKP ePset_Cost |
eBKP-H classification according to SN 506 511. Allowed values
|
Related elements
-
ARC-FIRE-ACOUSTIC-SEAL
Firestop / acoustic seal
Separates the installed seal from the opening and makes its type, performance, and quantity verifiable for tendering, construction, and operation.
-
ARC-CEILING
Suspended ceiling
Ensures coordinated room heights, ceiling design, and building services.
-
ARC-FLOOR-COV
Interior floor build-up
Provides a reliable basis for level coordination, joint design, tendering, and quantity take-off for interior finishes. Modelled in every room from tendering on; before that and in operation, the floor finish sits on the interior space.