Element

Ramp detailed

STR-RAMP pragmaticBIM.ch/str-ramp

Ensures early coordination of the structure, level transitions, and required gradient.

Ramp detailed (STR-RAMP)

Description

  • Execution-accurate geometry according to the structural design.
  • Authoritative federated model for execution planning, quantities, and coordination.

Modelling guidelines

  • Model with the correct slope as it will be built.
  • Maintain assignment to storey and structural part.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcRamp
IFC4.3
IfcRamp
IFC2x3
IfcRamp
Applicability rule
entity_ifc4=IfcRamp OR entity_ifc2x3=IfcRamp

Attributes

Name

Ramp designation according to the structural plan.

PredefinedType

Form of the ramp.

Allowed values

  • STRAIGHT_RUN_RAMP - straight ramp
  • TWO_STRAIGHT_RUN_RAMP - two straight flights
  • QUARTER_TURN_RAMP - L-ramp
  • TWO_QUARTER_TURN_RAMP - double L-ramp
  • HALF_TURN_RAMP - U-ramp
  • SPIRAL_RAMP - spiral ramp
Status Pset_RampCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
Bewehrungsgehalt 211.5_Beton_und_Stahlbetonarbeiten · kg/m³

Reinforcement content of the concrete component in kg/m³ according to the structural design.

Oberfläche 211.5_Beton_und_Stahlbetonarbeiten

Surface requirement and side reference of the concrete component for NPK tendering.

Betonqualität 211.5_Beton_und_Stahlbetonarbeiten

Concrete grade according to SN EN 206 for NPK tendering.

Allowed values

  • 0 - grade 0
  • A - NPK A (building)
  • B - NPK B (building)
  • C - NPK C (building)
  • D - NPK D (civil engineering)
  • E - NPK E (civil engineering)
  • F - NPK F (civil engineering)
  • G - NPK G (civil engineering)
  • P1 - dry pile concrete (NPK H)
  • P2 - underwater pile concrete (NPK I)
  • P3 - dry diaphragm wall concrete (NPK K)
  • P4 - underwater diaphragm wall concrete (NPK L)
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

Related elements

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel