Exclusion zone
STR-EXCL-ZONE
pragmaticBIM.ch/str-excl-zone
Keeps required structural volumes clear and prevents costly clashes with architecture and building services.
Description
- Volume where architecture and building services must not place anything (for example column axis, beam zone, opening reserve).
- Delivered by the structural engineer as a binding planning boundary, not modelled by the architect.
Modelling guidelines
- Model as a simplified proxy body; dimensions according to the structural design.
- Assign to the matching storey.
- Do not model reinforcement, execution details, or load-bearing components.
IFC entity
- IFC4
- IfcBuildingElementProxy
- IFC4.3
- IfcBuildingElementProxy
- IFC2x3
- IfcBuildingElementProxy
- Applicability rule
- {'de': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType=Sperrzone) OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType=Sperrzone)', 'fr': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Zone d\'exclusion") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Zone d\'exclusion")', 'it': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Zona di esclusione") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Zona di esclusione")', 'en': '(entity_ifc4=IfcBuildingElementProxy AND PredefinedType=USERDEFINED AND ObjectType="Exclusion zone") OR (entity_ifc2x3=IfcBuildingElementProxy AND ObjectType="Exclusion zone")'}
Attributes
| Attribute | Definition | Used in |
|---|---|---|
| Name |
Exclusion zone designation according to the structural design. |
|
| PredefinedType |
Marks the proxy as a user-defined type. Allowed values
|
|
| ObjectType |
Kind of proxy element. Allowed values
|
Related elements
-
STR-OPENING-VOID
Opening / recess (structural)
Transfers approved voids into the structural model as binding information so that clashes are avoided and penetrations can be built as planned.
-
STR-BEAM
Beam / girder detailed
Enables reliable coordination of load transfer, penetrations, and connections through to execution.
-
STR-COLUMN
Column detailed
Ensures coordinated load transfer and clash-free placement of adjacent components through to execution.