Element

Load-bearing interior wall

ARC-WALL-INT-LB pragmaticBIM.ch/arc-wall-int-lb

Makes load transfer and space separation jointly verifiable early on and provides a reliable basis for structural, fire, and acoustic coordination.

Load-bearing interior wall (ARC-WALL-INT-LB)

Description

  • Load-bearing wall between interior spaces according to the structural concept.
  • Used for coordination with structural engineering, fire and acoustic verification, and component identification.

Modelling guidelines

  • Model storey by storey; split at component and storey boundaries.
  • Set IsExternal=FALSE and LoadBearing=TRUE.
  • During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
  • Use and export the appropriate material from the authoring system.

IFC entity

IFC4
IfcWall
IFC4.3
IfcWall
IFC2x3
IfcWall
Applicability rule
(entity_ifc4=IfcWall AND IsExternal=FALSE AND LoadBearing=TRUE) OR (entity_ifc2x3=IfcWall AND IsExternal=FALSE AND LoadBearing=TRUE)

Attributes

Name

Wall designation according to the structural plan.

+2 more
PredefinedType

Kind of load-bearing interior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
+7 more
Reference Pset_WallCommon

Load-bearing interior wall reference according to the component catalogue.

IsExternal Pset_WallCommon

Marks an interior wall.

Allowed values

  • FALSE - interior wall
+6 more
LoadBearing Pset_WallCommon

Marks the wall as a load-bearing element in the architecture model.

Allowed values

  • TRUE - load-bearing element
+6 more
Status Pset_WallCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+4 more
FireRating Pset_WallCommon

Fire resistance class of the load-bearing interior wall according to the fire protection concept - load-bearing (R) or load-bearing with integrity and insulation (REI).

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
+3 more
AcousticRating Pset_WallCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

+3 more
ThermalTransmittance Pset_WallCommon · W/(m²·K)

Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component.

+3 more
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+3 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
+2 more
eBKP ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • C02.02 - interior wall construction
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic WandTypisierung. Example: Wand_Innen_Oberirdisch_Beton_200mm_REI90_53

+4 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+7 more
UnitPrice ePset_Cost · CHF/m²

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_WallBaseQuantities.NetSideArea is the authoritative reference quantity for UnitPrice.

+3 more
Connection ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

HazardType ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
GlobalTradeItemNumber Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

+1 more
SerialNumber Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

NetSideArea Qto_WallBaseQuantities · m²

Net side area of the modelled interior wall.

+8 more
Width Qto_WallBaseQuantities · m

Thickness of the modelled interior wall.

+5 more
GrossVolume Qto_WallBaseQuantities · m³

Gross volume of the modelled interior wall.

+2 more
FireRatingRequired ePset_WallRequirement

Required fire resistance of the component under the fire protection concept. Target value compared with FireRating.

+1 more
AirborneSoundInsulationMin ePset_WallRequirement · dB

Required airborne sound insulation Di [dB] between units under SIA 181. Target value compared with AirborneSoundInsulation.

+2 more
GlobalWarmingPotentialMax ePset_WallRequirement · kg CO₂-eq/m²

Maximum permitted greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area under the greenhouse gas target. Target value compared with GlobalWarmingPotential.

+1 more
AirborneSoundInsulation ePset_Wall · dB

Verified airborne sound insulation Di [dB] of the installed component under the acoustic verification.

+1 more
GlobalWarmingPotential ePset_Wall · kg CO₂-eq/m²

Greenhouse gas emissions from construction [kg CO₂-eq/m²] per square metre of component area, calculated from the build-up and KBOB life-cycle data.

Related elements

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel