Element

Beam / girder

ARC-BEAM pragmaticBIM.ch/arc-beam

Makes load-transfer zones visible early and prevents conflicts between the structure, spatial concept, and building services.

Beam / girder (ARC-BEAM)

Description

  • Coarsely dimensioned beam geometry according to the structural concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model as a simplified volume using the coordinated dimensions.
  • Do not model reinforcement, inserts, or detail connections.
  • During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
  • Use and export the appropriate material from the authoring system.
  • Export as a profile (IfcMaterialProfileSet); the profile designation is in IfcProfileDef.ProfileName, e.g. HEA200.

IFC entity

IFC4
IfcBeam
IFC4.3
IfcBeam
IFC2x3
IfcBeam
Applicability rule
entity_ifc4=IfcBeam AND LoadBearing=TRUE

Attributes

Name

Beam designation according to the structural plan.

+1 more
PredefinedType

Kind of beam.

Allowed values

  • BEAM - beam / girder
  • GIRDER - main girder
  • JOIST - joist
+8 more
LoadBearing Pset_BeamCommon

Marks the element as a load-bearing component in the architecture model.

Allowed values

  • TRUE - load-bearing component
+2 more
Status Pset_BeamCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
+1 more
FireRating Pset_BeamCommon

Fire resistance class of the beam according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
+1 more
CostInterface ePset_Cost

Cost interface: base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
+1 more
PlanningInterface ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
eBKP ePset_Cost

eBKP-H classification according to SN 506 511 and the CRB IFC ruleset.

Allowed values

  • C04.01 - floor slab
CalculatedType ePset_Cost

Calculated type name for cost and quantity grouping. Logic TraegerTypisierung. Example: Träger_Stahl_HEA200_5.20m

+2 more
ProductClass ePset_Cost

Product class as the shared key for costs, tendering, and life-cycle assessment. It is derived where material and component properties determine it unambiguously, otherwise set. In early phases, a reasoned assumption is acceptable.

Allowed values

+6 more
UnitPrice ePset_Cost · CHF/m

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

+2 more
ReferenceQuantity ePset_Cost

Qto_BeamBaseQuantities.Length is the authoritative reference quantity for UnitPrice.

+3 more
ElementStatus ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
+1 more
GrossVolume Qto_BeamBaseQuantities · m³

Gross volume of the modelled beam.

+1 more
Length Qto_BeamBaseQuantities · m

Length of the modelled beam.

+5 more

Related elements

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel