Healthcare
USE-HE
pragmaticBIM.ch/use-he
Examination, treatment and care of patients. Reference quantity: number of beds.
Boundary conditions
PG-24Level of care
The level of care and the number of beds, treatment places, and operating theatres determine wards, diagnostics, building services, and logistics.
Variants
-
VST-01Acute care
Acute hospital with emergency, surgery, and intensive care.
-
VST-02Rehabilitation
Clinic with therapy and training rooms.
-
VST-03Long-term care
Care home for longer stays.
-
PG-15Refit frequency
How often spaces, equipment, and installations are refitted decides how current the as-built data must be in operation. The more often the building is refitted, the more facility management use cases are preselected.
Scenarios
US-GE-01Reaching the unit (Described under another use)
US-HE-08Reaching the ward
Patients are moved in beds between ward, diagnostics, and surgery while visitors and supplies use the same floors. The access arrangement determines bed transport, hygiene, and separation of routes.
Variants
- Stairwell · Adds: Lobby, Stairwell
- Stairwell and elevator · Adds: Lobby, Stairwell, Elevator lobby
- Stairwell, elevator, and bed lift · Adds: Lobby, Stairwell, Elevator lobby, Bed lift
- Bed lift and separate service lift · Adds: Lobby, Stairwell, Elevator lobby, Bed lift, Service lift
US-HE-01Arriving and waiting
Patients and accompanying people arrive and wait for care. The calling system determines waiting area, travel, and privacy.
Variants
- Waiting room · Adds: Waiting room
- Direct rooming · Adds: Treatment room
US-GE-02Using the toilets (Described under another use)
US-GE-03Disposing of waste (Described under another use)
US-HE-02Examining and consulting
Professionals examine and consult patients. Room allocation determines transfers, privacy, and utilization.
Variants
- Examination room · Adds: Examination room
- Universal treatment room · Adds: Treatment room
US-GE-04Disposing of organic waste (Described under another use)
US-HE-03Providing treatment
Patients receive procedures of varying complexity. The procedure determines room type, support, and safety zones.
Variants
- Treatment room · Adds: Treatment room
- Procedure room · Adds: Procedure room
- Operating theatre · Adds: Operating theatre
US-HE-04Performing diagnostics
Professionals produce diagnostic images or analyse samples. The method determines specialist rooms, travel, and technical equipment.
Variants
- Imaging · Adds: Imaging room
- Medical laboratory · Adds: Medical laboratory
- External diagnostics
US-HE-05Observing and caring
Patients remain under observation after treatment or overnight. Length of stay determines privacy, monitoring, and care routes.
Variants
- Recovery room · Adds: Recovery room
- Patient room · Adds: Patient room
- Patient room with bathroom · Adds: Patient room, Bathroom
US-HE-06Moving medical goods
Materials and samples are supplied, used, and removed. Logistics determine storage, travel, and separation of clean and used goods.
Variants
- Supply room · Adds: Supply room
- Sample store with airlock · Adds: Airlock, Sample storage
US-HE-07Visiting
Relatives and friends visit patients during their stay. The visiting location determines privacy, disruption of care, and routes through the ward.
Variants
- Visit in the patient room · Adds: Patient room
- Visit in the cafeteria · Adds: Cafeteria
Use cases
-
BES-SEISMIC-MEPTender installation suspensions as a separate trade
Tender suspension of building services early as a separate trade so that design, coordination, and installation are clearly owned by one specialist contractor.
-
CON-ROOM-LABELManage fit-out room by room with a checklist
Keep the fit-out steps for each room in a shared checklist so that trades work to a takt and the status of every room is visible on site.
-
DES-DOORDerive the basis for door planning
Derive the door-design basis from the model so that door schedules and discipline coordination do not rely on scattered individual details.
-
HOV-PRODUCT-PASS-GTINLink the product passport via GTIN
Link product-passport information unambiguously to installed product types by GTIN without duplicating the complete manufacturer data in the model.
-
DES-SANITARY-FIXTURE-COORDCoordinate sanitary fixtures
Coordinate sanitary fixtures jointly, from first placement through to detailed plumbing design, so that connections and service linings match the approved locations and dimensions.
-
HOV-PRODUCT-PASS-SERIALLink the product passport via serial number
Assign product-passport information to an individual installed product by GTIN (Global Trade Item Number) and serial number, keeping its individual life cycle traceable.
-
DES-PHYSICSCreate the building physics requirements model
Translate the approved building physics concept into a spatially assigned requirements model so sound and thermal insulation can be checked unambiguously and continuously in the architecture model.
-
DES-SOUND-SIA181Derive SIA 181 sound insulation requirements from room use
Set the noise load and noise sensitivity of every room and derive the sound insulation requirement of every separating element from them, so missing or too low requirements between usage units show up before the tender.
-
DES-WALL-REQUIREMENTSCombine wall requirements from discipline reports
Combine fire protection and building physics requirements for each wall to create unambiguous requirement profiles and suitable wall types.
-
DES-MEP-SCHEMDevelop MEP schematics
Develop MEP system and riser schematics and formally approve them before construction.
-
DES-ARCH-MEP-COORDCoordinate architecture and building services
Coordinate MEP routes, equipment, and space requirements with architecture and update both discipline models consistently.
-
QAS-ARCH-STRUCT-COORDCoordinate architecture and structure
Coordinate load-bearing components between the architecture and structural models so that geometric deviations are detected before construction and do not have to be maintained twice.
-
QAS-ACOUSTICCheck sound and thermal insulation on components
Automatically check the architecture model against the approved building physics requirements model so sound and thermal insulation deviations become visible after every relevant design change.
-
QAS-ELEMENT-PERFCheck component types against performance requirements
Check wall, slab, window, and door component types against the performance requirements that follow from the chosen framework conditions, so every type demonstrably meets what was ordered.
-
QAS-INSTALL-PATHVerify installation access paths
Carry the installation access paths to be kept clear in the model and prove that equipment can be brought in - before large plant or components force alterations and deconstruction.
-
QAS-FURNISHABILITYVerify furnishability
Prove furnishability of interior rooms so clients can decide and approve without being able to read plans.
-
QAS-ACCESS-SIA500Verify accessibility to SIA 500
Make deviations from the accessible route visible before the permit submission, instead of discovering them only during the permit procedure.
-
QAS-SITE-LOGISTICSCheck site logistics across the construction phases
Plan site logistics volumetrically and keep them current across phases - before ramps, slopes, and space needs surprise on site.
More uses
-
USE-PR
Production
Manufacturing and processing of goods. Reference quantity: output per year.
-
USE-LO
Warehousing and logistics
Storage, handling and distribution of goods. Reference quantity: number of pallet places.
-
USE-SP
Sport
Individual and team sports, for example in halls, pools and facilities. Reference quantity: number of courts or hall units.