Use case Quality assurance Design certainty
Check sound and thermal insulation on components
QAS-ACOUSTIC
pragmaticBIM.ch/qas-acoustic
Automatically check the architecture model against the approved building physics requirements model so sound and thermal insulation deviations become visible after every relevant design change.
Starting point
- Manually transferring building physics requirements to the architecture model creates gaps, conflicting values, and substantial coordination effort.
- Spot checks often detect deviations between discipline planning, the component catalogue, and the architecture model too late.
Goal & benefit
- Automatically compare target values with envelope and separating components in the architecture model based on their spatial relationships.
- Identify missing, divergent, or ambiguous information early and document its resolution traceably.
Process
- Provide the approved building physics requirements model and the current architecture model.
- Automatically compare component location and sound and thermal insulation values with the target requirements.
- Document deviations, get a specialist assessment, and have the responsible designer resolve them in the requirements or architecture model.
Deliverable
- Checked architecture model with coordinated sound and thermal insulation information
- Traceable check report showing open, accepted, and resolved deviations
Ways to do it
-
BIMcollab Zoom BIMcollab editorial listing
IFC viewer and model checking with rules, colouring by properties and BCF issues.
Visit vendor · last checked
-
IFC-Lite LTplus AG editorial listing
Open-source IFC toolkit for browser, server and CLI to view, query, validate, edit and export models.
Visit vendor · last checked
-
Lesosai E4tech Software SA editorial listing
Checks thermal insulation only (U-values); sound insulation not covered.
Visit vendor · last checked
-
Solibri Office Solibri (Nemetschek) editorial listing
Rule-based checking of IFC models for clashes, model quality and requirements.
Visit vendor · last checked
Suggest a tool All tools and services
Elements involved
Architecture (17)
More use cases for Design certainty
-
QAS-DET-REF
Locate standard details in the model and check for gaps
Locate in the 3D model where each standard detail applies and check that everything is detailed, before gaps only show up during execution.
-
QAS-FIRE
Check fire resistance on components
Automatically check the architecture model against the approved fire protection requirements model so deviations become visible after every relevant design change.
-
QAS-ELEMENT-PERF
Check component types against performance requirements
Check wall, slab, window, and door component types against the performance requirements that follow from the chosen framework conditions, so every type demonstrably meets what was ordered.