Room type Housing

Lobby

RT-WH-12 pragmaticBIM.ch/rt-wh-12

Shared entrance hall of the building.

Room name code

RN-03-10-02 Lobby

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Lobby
Reference Pset_SpaceCommon VF
NetPlannedArea ePset_SpaceRequirement 80 m²
FloorCovering Pset_SpaceCoveringRequirements Schmutzschleuse
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Public
WinterTemperatureMin ePset_SpaceRequirement 16 °C
WinterTemperatureMax ePset_SpaceRequirement 20 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 100 lx
PeakOccupancy ePset_SpaceRequirement 10 Personen
DailyOperatingHours ePset_SpaceRequirement 12 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 300 m³/h

Equipment

Manoeuvring area SIA 500 1
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
min. 1, 1 per 10 m² net floor area
Light switch
  • preferred · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

Exterior door 1 (1-4)
Window 1 (min. 0)

More room types of this use