Room type Housing

Stairwell

RT-WH-10 pragmaticBIM.ch/rt-wh-10

Vertical circulation between storeys.

Room name code

RN-03-20-01 Stairwell

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Stairwell
Reference Pset_SpaceCommon VF
NetPlannedArea ePset_SpaceRequirement 20 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Internal
WinterTemperatureMin ePset_SpaceRequirement 16 °C
WinterTemperatureMax ePset_SpaceRequirement 20 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 100 lx
PeakOccupancy ePset_SpaceRequirement 10 Personen
DailyOperatingHours ePset_SpaceRequirement 12 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 300 m³/h

Equipment

Socket outlet
  • preferred · elevation
min. 1, 1 per 10 m² net floor area
Light switch
  • required · elevation
1

More room types of this use

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel