Elevator lobby
RT-WH-13
pragmaticBIM.ch/rt-wh-13
Landing in front of the lift on a storey.
Room name code
RN-03-20-02 Elevator lobby
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Elevator lobby | |
| Reference Pset_SpaceCommon | VF | |
| NetPlannedArea ePset_SpaceRequirement | 6 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal panel ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 4 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 3 | kN |
| SecurityLevel ePset_Space | Internal | |
| WinterTemperatureMin ePset_SpaceRequirement | 16 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 28 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 100 | lx |
| PeakOccupancy ePset_SpaceRequirement | 10 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 12 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 300 | m³/h |