Service lift
RT-CI-06
pragmaticBIM.ch/rt-ci-06
Lift for goods, staff, and service routes, separate from public lifts.
Room name code
RN-03-20-04 Service lift
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Service lift | |
| Reference Pset_SpaceCommon | VF | |
| NetPlannedArea ePset_SpaceRequirement | 6 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Hartbeton | |
| WallCovering Pset_SpaceCoveringRequirements | Beton roh | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal panel ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Workshop | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Restricted | |
| WinterTemperatureMin ePset_SpaceRequirement | 16 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 28 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 100 | lx |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 8 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |