Accessible toilet
RT-HY-03
pragmaticBIM.ch/rt-hy-03
Wheelchair-accessible toilet room.
Room name code
RN-04-10-03 Accessible toilet
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Accessible toilet | |
| Reference Pset_SpaceCommon | NNF | |
| NetPlannedArea ePset_SpaceRequirement | 4 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal sheet ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Internal | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 300 | lx |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
| HandicapAccessible Pset_SpaceCommon | TRUE |
Equipment
| Wheelchair-accessible WC | 1 |
| Wheelchair-accessible washbasin | 1 |
| Turning area SIA 500 | 1 |
Socket outlet
|
min. 1, 1 per 10 m² net floor area |
Light switch
|
1 |