Room type Education

Visitor toilet

RT-HY-10 pragmaticBIM.ch/rt-hy-10

Toilet room for visitors and customers, separate from staff.

Room name code

RN-04-10-07 Visitor toilet

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Visitor toilet
Reference Pset_SpaceCommon NNF
NetPlannedArea ePset_SpaceRequirement 15 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Plattenbelag
CeilingCovering Pset_SpaceCoveringRequirements Metal sheet ceiling
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 2 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN
SecurityLevel ePset_Space Internal
WinterTemperatureMin ePset_SpaceRequirement 20 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 22 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 300 lx
PeakOccupancy ePset_SpaceRequirement 1 Personen
DailyOperatingHours ePset_SpaceRequirement 1 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 30 m³/h

Equipment

Wall-hung WC 3 (min. 1)
Washbasin row or Washbasin 1
Socket outlet min. 1, 1 per 10 m² net floor area
Light switch 1

Openings

More room types of this use

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel