Boundary condition Boundary conditions
Sound insulation
PG-38
pragmaticBIM.ch/pg-38
This framework condition sets whether the minimum requirements under SIA 181 apply, or increased or special requirements. It drives partitions, slabs, and doors between dwellings or units.
Variants
-
SLS-01SIA 181 minimum requirements
Airborne and impact sound insulation meet the SIA 181 minimum requirements for the relevant noise sensitivity.
Activates: Create the building physics requirements model, Derive SIA 181 sound insulation requirements from room use, Check sound and thermal insulation on components
-
SLS-02SIA 181 increased requirements
The increased SIA 181 requirements apply, as is usual for condominiums. Every wall and slab between units gets a requirement profile.
Activates: Create the building physics requirements model, Derive SIA 181 sound insulation requirements from room use, Check sound and thermal insulation on components, Combine wall requirements from discipline reports, Check component types against performance requirements
-
SLS-03Special requirements
Individual spaces need more than the increased requirements, such as hotel rooms, treatment rooms, or studios. The acoustic consultant sets the values for each pair of spaces.
Activates: Create the building physics requirements model, Derive SIA 181 sound insulation requirements from room use, Check sound and thermal insulation on components, Combine wall requirements from discipline reports, Check component types against performance requirements
Activated use cases
DES · Design
-
DES-PHYSICSCreate the building physics requirements model
Translate the approved building physics concept into a spatially assigned requirements model so sound and thermal insulation can be checked unambiguously and continuously in the architecture model.
-
DES-SOUND-SIA181Derive SIA 181 sound insulation requirements from room use
Set the noise load and noise sensitivity of every room and derive the sound insulation requirement of every separating element from them, so missing or too low requirements between usage units show up before the tender.
-
DES-WALL-REQUIREMENTSCombine wall requirements from discipline reports
Combine fire protection and building physics requirements for each wall to create unambiguous requirement profiles and suitable wall types.
QAS · Quality assurance
-
QAS-ACOUSTICCheck sound and thermal insulation on components
Automatically check the architecture model against the approved building physics requirements model so sound and thermal insulation deviations become visible after every relevant design change.
-
QAS-ELEMENT-PERFCheck component types against performance requirements
Check wall, slab, window, and door component types against the performance requirements that follow from the chosen framework conditions, so every type demonstrably meets what was ordered.
More boundary conditions
-
PG-33
Earthquake
This framework condition sets the structure class under SIA 261 and, in a renovation, how far the existing structure is upgraded under SIA 269/8. It matters mainly when the client raises it or decides the degree of upgrading.
-
PG-11
Construction method & prefabrication
This framework condition determines whether the construction method remains open, is designed conventionally, or targets a high degree of prefabrication in timber, steel, or concrete. This choice determines when contractors must be involved, interfaces resolved, and shop, production, and assembly information provided.
-
PG-12
Security / critical infrastructure
This framework condition determines how strictly information and building security are handled for critical infrastructure: which CDEs are allowed and whether security-critical areas and building security measures must be managed and checked on a model basis.